Foundation Specifications for WTC River Intake Relocation

Machine-extracted title · confidence 95%

Construction specifications document detailing foundation requirements for the World Trade Center river water intake system relocation project.

NYC-WTC_000165112–000165243

Folder label: “WORLD TRADE CENTER - RELOCATION OF RIVER WATER INTAKE LINES & PUMP STATION ELECT. POWER & COMM. LINES

Page image
Scanned page image, NYC-WTC_000165162
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Battery Wrk City Commercial Center Bldg. ’B’ WTC River Water Intake System Relocations

2. Enlargement of existing 2O"}/5 prestressed concrete WTC river water pumped discharge pipe line to 66"0 reinforced concrete pipe and construction of new 66"0 line around Building 'B’ Gatehouse. 3. Connection of new 66”;!$ lines to existing 6O'’0 line and existing 20"^ line. 4. Pipe access manholes including frames, covers and ladders. S. Pipe anchors, supports, thrust blocks, cradles, and connections to pipe support foundations. 6. Air venting. 7. Pipe cleaning and testing. 8. Permits and fees. 9. Field fabricated reinforced concrete pipe - 6S''0. 10, Factory fabricated prestressed concrete pipe 2O"0. 11. Steel pipe liner. 12. Corrosion protective coatings. 13. Coordination of system shut-downs. 14. Removal of existing abandoned lines where inter­ ference occurs with installation of new work. 15. Staging of work to insure uninterrupted river water service to the existing World Trade Center refrigeration plant. 16. Sacrifical anode cathodic protection of steel lining of concrete pipes. 17. Furnishing and placing reinforced concrete and forms as required for piping. 18. Coordination with adjacent utilities. 19. Draining and refilling of existing and relocated piping systems. Coordinate scheduling of shut­ down and start-up of existing plant. Mechanical Special Conditions 15010-2

NYC-WTC_000165162

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165162Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165064 · Box DEP Box 44

Request documentation regarding the relocation of river water intake lines and pump station utilities at the World Trade Center.

Filed in the same folder

Compare copies and versions →