← Document results/DEP Box 44/WORLD TRADE CENTER - RELOCATION OF RIVER WATER INTAKE LINES & PUMP STATION ELECT. POWER & COMM. LINES
Document / 132 pages

Foundation Specifications for WTC River Intake Relocation

Machine-extracted title · confidence 95%

Construction specifications document detailing foundation requirements for the World Trade Center river water intake system relocation project.

NYC-WTC_000165112–000165243

Folder label: “WORLD TRADE CENTER - RELOCATION OF RIVER WATER INTAKE LINES & PUMP STATION ELECT. POWER & COMM. LINES

Page image
Scanned page image, NYC-WTC_000165231
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Battery Park CiJ^ Commercial Center Bldg. "B" WTC River Water Intake System Relocations

c. Fiberglass Tie Cord shall be: (1) Bishop (2) Quelcor H. Testing of High Voltage Cables 1, Wires and calbes shall be tested at the cable manufacturer’s plant in accordance with require­ ments of the Insulated Power cable Engineers As­ sociation (IPCEA) and AEIC Standards. The con- t.ractor shall make all arrangements for the tests. 2. All wires and cables shall be tested in accor­ dance with the requirements of the above publica­ tions for voltage test. For cable rated less than 5,000 volts, only the A.C. test will be re­ quired. For cables rated at 5,000 volts, the IPCEA and AEIC direct current test procedures for cables rated 5,001 volts and higher will be re­ quired in addition to the A.C. test procedure as described below. 3. A Direct Current Test, similar to that performed on 5001 volt and higher rated cable except that the following voltage levels shall apply: a. Ethylene Propylene Rubber Insulated Poly­ ethylene Jacketed - 35.0 KV. b. Cross-Linked Thermosetting-Polyethylene In­ sulated Cable 35.0 KV. 4. 5'?here required by the Port Authority Engineer, a D.C. test shall be performed on the installed cab.le at the time of installation and. thirty (30) days after installation. The applicable D.C. voltage values are as follows: a. Ethylene Propylene Rubber insulated poly­ ethylene jacketed - 25.0 KV. b. Cross-Linked Thermosetting-Polyethylene In­ sulated Cable - 25.0 KV.

Electrical Work 16020-21

NYC-WTC_000165231

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165231Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165064 · Box DEP Box 44

Request documentation regarding the relocation of river water intake lines and pump station utilities at the World Trade Center.

Filed in the same folder

Compare copies and versions →