NYC-WTC_000093788
Fax transmittal from the Mayor's Office regarding a March 2002 meeting with the building group.
52 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Forwarded programmatic agreement documentation addressing post-disaster building cleaning procedures and eligible building list for recovery efforts.
NYC-WTC_000164903–000164928
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
1. Minor interior mechanical (HVAC), electrical, or plumbing work, limited to upgrading, elevation, or in kind replacement, with the exception of historic fixtures, which must be repaired in kind for this Allowance to apply. This Allowance does not apply to exposed new ductwork.
2. Replacement or installation of interior fire detection, fire suppression, or security alarm systems. This Allowance does not apply to exposed wiring such as surface mounted wiring, conduits, piping, etc.
C. Windows and Doors
1. In kind repair or replacement of damaged or deteriorated windows and doors.
2. Replacement of window panes in kind or with clear double or triple glazing, provided the result does not alter the existing window material and form. Also, historic windows or glazing may be treated with clear window films. This Allowance does not apply to the replacement of existing archaic or decorative glass.
3. In kind repair of historic door and window hardware.
D. Exterior Walls, Cornices, Porches and Foundations
1. Cleaning to remove surface dirt consistent with Appendix B P, Performance Standards for Cleaning Masonry Exteriors.
2. Cleaning to remove paint (signage) from masonry exteriors consistent with Appendix B, Performance Standards for Removing Paint (Signage) from Masonry.
3. Repainting of surfaces, provided that destructive surface preparation treatments are not used, such as water blasting, sandblasting, power sanding, and chemical cleaning.
4. In kind repair or partial replacement of porches, cornices, exterior siding, doors, balustrades, stairs, or trim.
5. Substantially in kind repair or replacement of signs or awnings.
6. Temporary stabilization bracing or shoring, provided such work does not result in additional damage, significant loss of historic fabric, or irreversible alterations.
7. Anchoring of walls to floor systems, provided the anchors are embedded and concealed from exterior view, such as in the Hilti systems, and disturbed historic fabric is restored in kind.
13
NYC-WTC_000164916
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000093788
Fax transmittal from the Mayor's Office regarding a March 2002 meeting with the building group.
52 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150931
Cover fax from the Mayor's Office forwarding DEP documents regarding exterior clean-up to be reviewed before a meeting with building owners.
48 shared non-person entities · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093746
Letter from FEMA providing a list of historic buildings and recommended cleaning treatments for post-disaster recovery.
46 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094043
Letter from FEMA providing a list of historic buildings and recommended cleaning treatments for post-disaster recovery.
47 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
7 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141674
Draft Programmatic Environmental Assessment for World Trade Center recovery activities dated January 24, 2002.
4 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115479
Application for a license agreement between the City of New York and a landowner to clean exterior areas at 23 Park Row.
5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115561
Attorney letter regarding legal proceedings between environmental protection authorities and property owners at 29 Park Row.
5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099382
DEP license agreement for debris removal at 87 Nassau Street dated 2002.
4 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115195
License agreement dated July 2002 between the City of New York and Atlanta 3 LLC authorizing debris removal at 215 Pearl Street.
5 shared non-person entities · 1 shared topics · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000093788
Fax transmittal from the Mayor's Office regarding a March 2002 meeting with the building group.
Similar indexed content
NYC-WTC_000150931
Cover fax from the Mayor's Office forwarding DEP documents regarding exterior clean-up to be reviewed before a meeting with building owners.
Similar indexed content
NYC-WTC_000093746
Letter from FEMA providing a list of historic buildings and recommended cleaning treatments for post-disaster recovery.
Similar indexed content
NYC-WTC_000094043
Letter from FEMA providing a list of historic buildings and recommended cleaning treatments for post-disaster recovery.
Similar indexed content
NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
Similar indexed content