NYC 9/11 Public Portal Document 14. fax or alternative format agreed upon and within two days ofrequest. Final air sampling shallbe performed with 24 hours of final visual inspection. Post Clean-up Air Sampling Procedures a. Sampling shall not begin until a visual inspection confirms the absence of visible dust and debris. Post cleaning air sampling shall be performed upon successful visual inspection and completed within 24 hours Within 24 hours of what?. A successful visual inspection shall be an inspection that verifies the absence of dust and debris. b. C. All surfaces must be completely dry prior to the start of sampling. Window air conditioning units where applicable shall be run/operated at least 15 minutes prior to the start of sampling. The air conditioning units shall operate continuously throughout the sampling. Why is the air conditioning unit operated after clean up when it wasn't operated during sampling prior to clean up? It should be operated during sampling priorto clean up as well: d. Upon completion of the cleaning, either aggressive or modified aggressive air sampling procedures will be conducted to verify attainment of the clean-up criteria. Aggressiveor modified aggressive air sampling will be used for Seope A clean-ups, based on consultation with resident. In aggressive air monitoring sampling situations, before the start of sampling, a l horsepower electrie leaf błower will be used to direct exhaust air against walls, eeilings. floors and other surfaces. When directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal belongings. The procedure described bełow for modified aggressive sampling techniques will also be emptoyed e. In modified aggressive sampling, one 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low speed. The fan shall operate continuously throughout sampling and shall not be turned off until sampling is completed. When should this fan be turned on? f. For studio apartments 3 air samples shall be collected. For 1-bedroom apartments and above 5 air samples shall be collected. Sampling equipment shall be placed in living areas and away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces. g Common spaces will be sampled without the tise of forced air devices (fans, leaf błowers ete). For small spaces, less than 160 square feet, 3 air samples will be collected. Forlarge spaces greater than 160 square feet and less than 25,000 square feet 5 air samples will be collected. For spaces greater than 25,000 square feet, 1 air sample will be collected for each 5,000 square feet. Sampling equipment shall be placed away from obstructions. The sampling cassette must be placed on a tripod directed downward at a 45 degree angle and not taped to existing surfaces. h Air samples shall be collected in accordance with the procedures specified in NIOSH 7400 Method for PCM and 7402 for TEM. Air sampling cassettes need to be monitored to ensure pumps are not clogging by monitoring flow rates. The minimum sampling volume required is 3600 liters. i. 24-hour turn-around-time shall be specified for the analysis of all post-cleaning air samples for Scope B cleanups. The contractor shall document all the necessary information regarding sampling activities, fill NYC-WTC_000164041
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
NYC-WTC_000163947
EPA distribution of inter-agency coordination matrix to federal, state, and local agencies regarding post-9/11 environmental response.
15 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000139560
Updated WTC monitoring scope of work including technical notes on dust control methods and equipment.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140385
Specific instructions for collecting bulk dust samples, labeling containers, and repairing insulation disturbed during sampling activities.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140430
Draft contract detailing EPA and DEP collaboration on residential dust sampling and cleaning services for residents south of Canal Street.
11 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140537
Draft scope of work document detailing compliance requirements and procedures for residential cleaning and air sampling south of Canal Street.
12 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139482
Forwarded revised scopes of work for cleaning and monitoring contracts related to WTC indoor air quality.
12 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140626
Draft scope of work for WTC debris/dust residential cleanup program with compliance requirements and regulatory overview.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138725
EPA transmits revised scopes of work for WTC indoor cleaning and monitoring contracts to DEP.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139539
Updated scopes of work for WTC cleaning and monitoring contracts distributed to multiple agencies for coordination.
14 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140306
Procedures for obtaining work authorization, monitoring residential and HVAC cleaning, and reporting hazardous conditions to EPA.
10 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000139560
Updated WTC monitoring scope of work including technical notes on dust control methods and equipment.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140367
Scope of work excerpt detailing visual inspection requirements and air conditioning protocols prior to post-cleaning air sampling.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140626
Draft scope of work for WTC debris/dust residential cleanup program with compliance requirements and regulatory overview.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139539
Updated scopes of work for WTC cleaning and monitoring contracts distributed to multiple agencies for coordination.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139101
EPA transmits revised scopes of work documents for the indoor dust cleaning and monitoring program, including cleaning SOW #7 and monitoring SOW #7.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139101
EPA transmits revised scopes of work documents for the indoor dust cleaning and monitoring program, including cleaning SOW #7 and monitoring SOW #7.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000139560
Updated WTC monitoring scope of work including technical notes on dust control methods and equipment.
Cited alongside this record in an Ask answer
NYC-WTC_000138626
Distribution of revised scopes of work documents for WTC indoor cleaning and monitoring contracts.
Cited alongside this record in an Ask answer
NYC-WTC_000139539
Updated scopes of work for WTC cleaning and monitoring contracts distributed to multiple agencies for coordination.
Cited alongside this record in an Ask answer
NYC-WTC_000139957
Record of differing agency views on asbestos containment requirements and public signage during cleaning operations.
Cited alongside this record in an Ask answer
NYC-WTC_000139991
Summary of disagreements between the EPA and DEP regarding asbestos containment requirements and public signage for HVAC cleaning operations.
Cited alongside this record in an Ask answer