a. Sampling shall not begin until a visual inspection confirms the absence ofvisible dust and
debris. Post cleaning air sampling shall be performed upon successfid visual inspection and
completed within 24 hours. A successful visual inspection shall be an inspection that
verifies the absence of dust and debris.
b. All surfaces must be completely dry prior to the start of sampling.
c. Upon completion ofthe cleaning, air sampling will be conducted to verify attainment ofthe
clean-up criteria. Based on considtation with the resident or owner, aggressive or modified
aggressive air sampling will be conducted. Residents shall not be present during
aggressive air sampling.
i. Before beginning aggressive air sampling, a 1 horsepower electric leafblower shall
be used to direct exhaust air against walls, ceilings, floors and other surfaces. This
shall continue for at least five minutes per 1,000 square feet of floor. When
directing the exhaust, caution shall be taken to minimize disturbance and potential
damage to furnishings and personal belongings
ii. Residents shall not be present in their residence during aggressive air sampling
activities.
iii. Personal protective equipment including disposable clothing, gloves, and
respirators shall be worn during aggressive air sampling activities.
iv. HVAC systems shall be shut down or isolated locally during aggressive air
sampling.
V. Room and window air conditioners shaUnot be operated during aggressive air
sampling.
vi. Leaf blowers shaUnot be employed for modified aggressive air sampling.
vii. All other procedures are identical for aggressive and modified aggressive air
sampling, unless otherwise noted.
d. At least one 20-inch fan shall be placed in the center of each room sampled. One fan per
10,000 cubic feet ofroom space shall be used. The fans shall be operated on slow speed
and pointed toward the ceiling. The fans shall run for at least 15 minutes prior to the start
of sampling. The fans shall operate continuously throughout sampling and shall not be
turned off until sampling is completed.
e. For studio apartments 3 air samples shall be collected. For 1 -bedroom apartments and
above, 5 air samples shall be collected. Sampling equipment shall be placed in living areas
and away from obstructions. The sampling cassette must be placed on a tripod, not taped
to existing surface and should be directed downward at a 45 degree angle.
f. Common spaces will be sampled without the use offorced air devices (fans, leafblowers
etc). For small spaces, less than 160 square feet, 3 samples will be collected. For large
spaces greater than 160 square feet and less than 25,000 square feet 5 samples will be
collected. For spaces greater than 25,000 square feet, 1 sample will be collected for each
5,000 square feet. Sampling equipment shall be placed away from obstructions. The
sampling cassette must be placed on a tripod directed downward at a 45 degree angle and
not taped to existing surfaces.