NYC 9/11 Public Portal Document
A third. Monitoriiig Contractor will perform air monitoriag. Pmonal air nionitoriag'will bepodrirmed
on a minimum ofone worker per shift per apartment duri.ag the first 4-6 weeks ofcleaning opefations.
Thereafter, personal air samples will be taken randomly at arate of one sample per quadrant per day.
These results of this sampling shall be sent immediately to EPA, DEP, OSHA and the employer. The
employer will make these results . available to the emptoyees or their designated representatives for their
review in accordance with 29 CFR 1910.1001 and 29 CFR 1926.58. .9,
C. Qualifications ' < /
All work shall be perfdrnaed by aNYS DQL licensed contractor with NYS 1)(ft, and NAT.' DEP certified
workers. Proof of qualifications must be presented upon request.
P. .Specifleatipps ' ; ■
This contract shall be in force for 18 consecutive months from the eomnicneemenl dale. Contractors fflust
be prepared to mobilize within 72 hours of the contract aw ard. ('ontractora shall have on staff and
assigned to this contract a sufficient number of properly trained and cerli lied w orkers to clean 20 units
simultaneously and complete the clean up activities w ithin each unit w iihi n 2 days. Activities shall be
coordinated with the project monitor to ensure that the \"isHal inspection is performed within two hours of
the completion ofclean-up activities. Cleaning activities sha 11 be considered completed upon successfill
\isiial inspection by the Project Monitor. Copies ofall invoices for work conducted under this contract
shall be provided to USEPA and DEP.
The contractor shall prepare a Health and Safety Plan (I I ASP) in with 29CFRl91().l02f) and 29 GFR
1926.58. All personnel iin olved in residential cleaning activities shall follow the contractor 1 lASP prepared
by their employer. EP A shall be provided w i i h a copy oft 1 le employ er HASP prior to the start ofwork.
A11 cleanup operations will be conducted i n accordance with either Scope A or Scope B as described
below. i ■
HEPA means a filter system capable oftrapping and retaining 99.97% ofall mono-dispersed particles of
0.3 micrometers in diameter. '
111‘PA vacuum means a vacuum cleaner equiped with a H EP A filter, with a static waterlift of 95 to 100
indies of static water lilt.
Scope of Work A 7 •
Application: These procedures apply to the ciean-upofminimal dust^cumiilatioas (light coating). • If a
\isiial inspection indicates the presence of significant accumulations ofdust and/or dehrisfirmfhe collapse
ofthe WTC Scope B procedures shall applied (refer toScope ofWork B). 'Residents maybe present during
Scope A cleaning procedures.
1. Cleaning of Common Spaces • • / •
Common spaces including hallways, stairways and elevators Interiors will be cleaned if
NYC-WTC_000163866
OCR can misread numbers and units. Confirm readings against the page image before using them.