Wipe Sampling Technicians Wipe sampling technicians must have 1 year experience in wipe sampling for a variety of contaminants. Employees shall have received state certified training in dust sampling. At a minimum at least 2 Wipe Sampling Technicians must be assigned to this project.

Analytical Laboratory The New York State Department of Health must certify the environmental laboratory. Certification for all the analytes of interest must have been maintained for at least six consecutive proficiency testing rounds. Laboratory must possess a Gas Chromatograph equipped with a capillary column and a high resolution Mass Spectrometer for analyzing Dioxin and Inductively Coupled Plasma for Total Metals. Cold Vapor Method apparatus be used for Mercury analysis.

Proof of qualifications must be presented upon request to the DEP.

Specifications

Work area preparation and cleaning activities of the building interior is expected to be completed within 3 weeks. The monitoring contractor must be prepared to mobilize within 72 hours of the contract award. Cleaning activities shall be scheduled for 20 units per day. Air sampling shall be scheduled and completed within 24 hours of successful visual inspection by the Project Monitor.

Sampling equipment must be in sufficient quantity to provide the amount and type of samples required for this project. At a minimum the following equipment are required: air-sampling pumps with maximum flow rate capacity of 15 liters per minute, tripods, rotometers, sample cassettes with mixed cellulose ester filters having pore size of 0.8 microns, micro vacuum, disposable porous cellulosic towellette moistened with wetting agent and solvent-wetted sampling agent.

Laboratory must have all analytical instruments on site wi1h sensitivities to the lowest level of detection as required by the analytical methods for each analyte.

All appropriate data, original field forms/data sheets, chain of custody forms and typed reports must be accurate and complete before submittal to DEP.

Project Monitoring

The project monitor shall provide oversight of clean-up activities to ensure compliance with project specifications, tenants authorizations, and applicable rules and regulations. The project monitor shall be present on site during all cleaning activities. The project monitor shall coordinate all scheduling requirements for timely completion of the work (completion of work area preparation and cleaning activities is expected to be completed within 3 weeks). The project monitor shall maintain the inventory of valuable items in each unit as

2 of 8

NYC-WTC_000163362

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000163362Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →