NYC 9/11 Public Portal Document
WKP W!
LABORATORIES, INC
AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CUENT; WARREN & PANZER ENGINEERS, P.C. TURNAROUND TIME 24HRS
WKP PILE# 501-01 SaMPLSOATE «/1M2
WKP LOO I.D.# N0204126. N0204127, and N0204129 ftSCSlVSD DATE <i;i«U02
Contract#: WTCAR2 ANALYSIS OATS //16,'O2
REPORT DATE 11/17/02
CLIENT JOB; NYC Department of Environmental Protection
CLIENT JOB#; 1079.01.01
location s.w.Afaa/ Site Map
ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400, NIOSH PAT Lad NO. 07186; NY
COLLECTION DEVICE: 25 irm MCE Filter Casserte; Collection Area = 386 so T-m;
SAMPLE WERE COLLECTED BY: Benny Giambnona, J. Garaa. and B. Osonnalke
SUMMARY OF ANALYSIS
CUBNT FIBERS/ fibers/
SAMPLE# Sita# SAMPLE LOCATION Vol. eq mm cc
1079.01.01 001 27 Gateway PlsJa Park Area 67S 2.50 <0.004
002 31 South End Ave. and Albany street 87S 0.00 <0.004
003 32 West street and Albany Place 875 6.40 0.004
004 33A Rector Place by the Park Place 678 0.00 <0.004
003 34 W. Thames street - Along Waterfront 67S 5.10 <0.004
006 37 West of Third Place 675 0.00 <0.004
007 S West Street and Warren street 875 7.80 0.004
008 4 RIvar Terrace and Chambers street 875 0.00 <0,004
009 6A River Terrace Park Area Between Park Place and Warren Street 675 6.40 0.004
010 9 River Terraca and Park Place West 675 2.50 <0.004
oil 17 River Terrace and Vesey 875 6.40 0.004
012 7 Warren Street and North Eld Avenue 67S 0.00 <0.004
013 10 North End Avenue Park ptace West 675 0.00 <0.004
014 29 Trinity Place end Themes Streat 67S 6.40 0.004
013 21 Pulton and Church Street STS S.1D <0.004
018 20A Vasey Street and West Broadway 875 0.00 <0.004
017 16 Park place and Church Street 676 0.00 <0.004
018 12 Murray Street and Church street 073 0.00 <0.004
019 15 Park Piece and Greenwich Street 676 9.60 0,003
020 11 Murray Street end Greenwich Street 875 0.00 <0.004
021 Field Blank 0.00
022 Field Blenk 0.00
NOTES; 1. S.5 fibers/lOO fields was used to oa
2. Samples were not collected by WKP Laboratories. Ino.
3. The Federal EPA Clearance Critical lollowirtg an asbestos abalemant project is 0.010 fibers/co.
4. PCM air samples win be disposed of alter 3 menths unless otherwise directed by client in writing.