NYC 9/11 Public Portal Document
WKP BjwiHSiRW
LABORATORIES, INC
AIR SAMPLE ANALYSIS REPORT
BK3
PHASE CONTRAST MICROSCOPY
CLIENT: WARREN & PANZER ENGINEERS, P.C- TURNAROUND TIME 24HRS
WKP FILE# 801-01 SAMPLSOATE 4/26/02
WKP LOG I.D. # N0Z04Z13, N0204216, and N02C4217 RBCBIVEO DATE 4/3Se2
Contract#: WrCARZ analysis date 4/25/02
REPORT DATE 4/26/02
CLIENT JOB; NYC Department of Environmental Protection
CLIENT JOB#; 1070.01.01
LOCATION S.W, Area/Site Map
ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab NO. 07186; NY
COLLECTION DEVICE; 26 mm MCE Filler Cassette; Collection Area » 365 st) mm;
SAMPLE WERE COULgCTEO BY: Benny Giembnone, J. Garcia and Pasty Osemwegie
SUMMARY OF ANALYSIS
CLIENT FIBERS/ FIBERS/
SAMPLE# Site# SAMPLE LOCATION Vol. sq mm co
1070,01.01 001 27 Gateway Plaza Part Area ere 0.00 <0.004
002 31 South End Ay«. and Albany Street 675 1.90 <0.004
003 32 West Sheet and Albany Place 676 1.30 <0.004
004 33A Rector Place by the Park Place 676 0.00 <0.004
008 34 W. Thames Street - Along Waterfront 676 1.30 <0.004
006 37 West of Third Place 878 0.00 <0.004
007 6 West Street and Warren Street 678 0.00 — 0.004
006 4 River Terrace and Chambers Streel 675 0.00 <0.004
009 6A River Terrace Park Area Between Park Place and Warren Street 675 0.00 <0.004
010 9 River Terrace and Park Place West 675 0.00 <0.004
Oil 17 River Tanace and Vesey 678 0.00 <0.004
012 7 Warren Street and North End Avenue 676 0.00 <0.004
013 10 North End Avenue Park place West 678 0.00 <0.004
014 29 Trinity Place and Thames Street 675 2.30 <0.004
015 21 Fulton and Church Street 675 o.oo <0.004
016 20A Vesey Street and West Broadway 675 1.30 <0.004
017 16 Park place and Church Street 675 0.00 <0.004
DIB 12 Murray Street and Church Street 678 0.00 <0.004
018 18 Park Place and Greenwich Street 675 0-00 <0.004
020 11 Murray Street and Greenwich Street 675 1.30 <0.004
021 Field Blank 0.00
022 Reid Blank 0.00
NOTES; 1,5.5 fibera/lOO fields was used to calculate the limit of detection (LOD).
2. Samples were not collected by WKP Laboratories, Inc.
3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/co.
4, PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.
Louis Lombardi
LABORATORY ANALYST laboratory director
NYC-WTC_000161770