December 17, 2002 114 LIBERTY STREET REMOVAL OF DUST, DEBRIS, AND CONTAMINATED MATERIALS
C. Hot Water Heater: If needed, provide appropriately sized UL rated electric water heaters to supply hot water for Personnel Decontamination Enclosure System Shower(s). Activate each water heater from 30 AMP Circuit breakers located within the Decontamination Enclosure sub panel. Provide relief valve(s) compatible with water heater operations, pipe relief valve down to drip pan at floor level with type "L" copper lining. Drip pans shall be 6" deep and securely fastened to water heater. Wiring of the water heater shall be in compliance with NEMA, NECA, and UL standards.
D. Hot Water: May be secured from the building hot water system, provided back flow protection is installed at point of connection as described in this section under Temporary Water Service connection, and if authorized by the Owner.
2.04 ELECTRICAL SERVICE:
A. General: Comply with applicable NEMA, NECA, and UL standards and governing regulations for materials and layout of temporary electric service.
B. Temporary Power: Provide service to decontamination unit sub-panel with minimum 60 AMP, 2 pole circuit breaker, or fused disconnect connected to the building's main distribution panel. Sub-panel and disconnect shall be sized and equipped to accommodate all electrical equipment required for completion of the Work.
C. Voltage Differences: Provide identification warning signs at power outlets that are other than 110-120 volt power. Provide polarized outlets for plug-in type outlets, to prevent insertion of 110-120 volt plugs into higher voltage outlets. Dry type transformers shall be provided where required to provide voltages necessary for work operations.
D. Ground Fault Protection: Equip all circuits for any purpose entering work area with ground fault circuit interrupters (GFCI). Locate GFCIs exterior to work area so that all circuits are protected prior to entry to the work area. Provide circuit breaker type ground fault circuit interrupters (GFCI) equipped with test button and reset switch for all circuits to be used for any purpose in work area, decontamination units, exterior, or otherwise required by NEC, OSHA, or other authority. Locate in panel exterior to work area.
E. Power Distribution System: Provide circuits of adequate size and proper characteristics for each use. In general, run wiring overhead, and rise vertically in such a manner to be least subject it to damage from operations.
F. Temporary Wiring: In the work area, temporary wiring shall be type UF non-metallic sheathed cable located overhead and exposed for surveillance. Provide liquid tight enclosures or boxes for ail wiring devices. Do not wire temporary lighting with plain, exposed (insulated) electrical conductors.
G. Electrical Power Cords: Use only grounded extension cords; use hard service cords where exposed to traffic and abrasion. Use single lengths ofcords only.
2.05 FIRST AID:
A. Comply with all governing regulations and recognized recommendations within the construction industry. A First Aid kit, in compliance with ANSI Z308.1, appropriate for the size of the working crew, shall be available at the project site at all times. 27 © AMBIENT GROUP, INC. -2002 TEMPORARY FACILITIES
NYC-WTC_000155555
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
48 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗47 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155168
Draft cleaning procedures and contract documentation for 114 Liberty with minor revisions, shared with EPA for review and comment.
12 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000138892
Forwarding draft cleaning procedures for 114 Liberty Street to EPA for review and comments.
12 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 114 Liberty Street · 16 pages · confidence 0.70 · verify page 79
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer