Ambient Dust Sampling Protocol Near WTC, Oct 2001

Machine-extracted title · confidence 95%

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

NYC-WTC_000153258–000153278
Page image
Scanned page image, NYC-WTC_000153264
OCR text

OCR status: ok · source: pdftotext

z s Z ■<

o co

'2 o o ****DRAFT Version 10, October 29, 2001**** ■D c CT o' cn "0 o o KJ CJ> Sample/Analytical Methods 9L O Parameter Environmental.Media Sampling/Analytical Method Sample Flow/time Analytical LOD / LOQ* o o c 3 Asbestos** I/O*** air NIOSH 7400, NIOSH 7402 16L/min-4hr(3840L) 0.010 fee (LOQ) o 3 Breathing zone sample height 5 hr (4800L) 0.008 fee 6hr(5760L) 0.007 fZee Total Suspended O '’ir EPA Method # (continuous realtime) 12-hr Particulates Breathing zone sample height ON HOLD? PM 10 and PM2..^ O air EPA Method # (continuous real-time) 12-hr ON HOLD? Breathing zone sample height Inhalable (< 100pm) I/O air lOM personal sampler. Analyze each 2 L/min -5 hr (600L) 30 ug / 50 ug/m’ thoracic (<10pm) fraction for crystalline silica, gypsum, respirable (<2.5pm) fiberglass, and calcite (XRD) Respirable I/O air NIOSH 7500 2.5 L/'min-5.3 hr(800L) 5 ug / 6 ug/m’ crystalline silica

pH I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g

asbestos I/O dust NIOSH 9002 (PLM), and if <1%TEM silica, gypsum, I/O dust XRD (C

gypsum, fiber­ glass, calcite

LODiLimit of analytical detection; LOQ: Limit of analytical quantitation ** use professional ju> yement re: asbestos sampling times to avoid filter overload (collection of 2 samples with different sampling times may be necessary) *** I: indoor; O: outdoor

Page 7 of

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000153264Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →