z z
■<
o o
i
1^
co
■D
o
o
Sample/Analytical Methods [NOTE: action/screening levels will dictate detection limit needs and will change sample times] c
CT
o
o'
cn
KJ Parameter Environmental.Media Sampling/Analytical Method Sample Flow/time Analytical LOD / LOO* "0
o
CD
9L
Asbestos I/O” air NIOSH 7400, NIOSH 7402 2 L/min / 4 hrs? O
o
Breathing zone sample height o
c
3
CD
Total Suspended O air EPA Method # (continuous realtime) ? 3
Particulates Breathing zone sample height
PM10andPM2.5 O air EPA Method # (continuous real-time) ?
Breathing zone sample height
Inhalable (< 100pm) I/O air lOM personal sampler. Analyze each 2 L/min / 4 hrs?
thoracic (<10pm) fraction for asbestos,(TEM), and for
respirable (<4pm) crystalline silica, gypsum, calcite
(XRD)
1
Respirable I/O air NIOSH 7500 2.2 L/min / 4 hrs?
crystalline silica
pH I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g
asbestos I/O dust PLM, and if <1% TEM ?
asbestos, gypsum, I/O dust XRD ?
mica, calcite
magnesium I/O dust ICP (EPA? NIOSH?) ?
’ LOD:Limit of analytical detection; LOQ: Limit of analytical quantitiation
” 1: indoor; O: outdoor
Page 7 of
OCR can misread numbers and units. Confirm readings against the page image before using them.