ro Sample/Analvtical Methods 3.
03
Parameter Environmental Media Sampling/Anaivtical Method Sample Flow/time Analytical LODZLOO* o
o
o
Asbestos** I/O’** air NIOSH 7400, NIOSH 7402 16 L/min -4 hr (3840L) 0.010 f/cc (LOQ) c
0.008 f/cc 3
Breathing zone sample height 5hr(4800L) CD
6hr(5760L) 0.007 f/cc
Inhalable (< 100pm) I/O air ACGIH/ISO sampling criteria 4 L/min -3.2 hr (750L) 30 ug / 40 ug/m’
particles Gravimetric, XRD (crystalline
silica, gypsum, mica, and calcite),
and SEM (fibrous glass).
Thoracic (<10pim) I/O air EPA IP-lOA/Gravimetric, 4L/min-3.2 hr(750L) 30 ug/ 40 ug/m’
particles XRD (crystalline silica, gypsum,
mica, and calcite), and SEM
(fibrous glass)
Respirable I/O air NIOSH 7500/ 2.5 L/min-5.3 hr(800L) 5 ug / 6 ug/m^
crystalline silica Gravimetric, XRD (gypsum
and respirable (<4pm) mica, and calcite), and SEM 30 ug/ 90 ug/m^
particles (fibrous glass)
Respirable (<2.5pm) I/O air EPA IP-lOA/Gravimetric 4L/min-3.2 hr(750L) 30 ug/ 40 ug/m^
particles XRD (crystalline silica, gypsum,
mica, and calcite), and SEM
(fibrous glass)
pH I/O dust EPA SW 846 Mtd 9045C (soils) 10-25 g
asbestos I/O dust NY State Method 198.1 (PLM) 10-25 g
and if <1% NY State Method
198.4 (TEM)
silica, gypsum, I/O dust XRD (SEM for fibrous glass) 10-25 g
fiberglass, mica,
and calcite
LOD:Limit of analytical detection; LOQ: Limit of analytical quantitation
** use professional judgement re: asbestos sampling times to avoid filter overload (collection of 2 samples with different sampling times
may be necessary)
7