NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 11/LAND FILL
Document / 73 pages

Environmental Health and Safety Plan draft for Staten Island Landfill,

Machine-extracted title · confidence 95%

Review draft of an environmental health and safety plan for debris operations at Staten Island Landfill.

NYC-WTC_000150335–000150407

Folder label: “LAND FILL

Page image
Scanned page image, NYC-WTC_000150366
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Staten Island Landfill Debris Disposal Operation Health and Safety Program

when ambient weather exceeds 75 degrees Fahrenheit measured as a Wet Bulb Globe Temperature (WBGT) as defined by the American Conference of Governmental Industrial Hygienists (ACGIH). Heat stress wll be evaluated based on three fectors accordingly:

WBGT base index determined by environmental data. Correction of WGBT base index for use of personal protective equipment. Correction of WBGT base for variations of work loads.

The resulting WBGT index will be used to calculate a Threshold Limit Value (TLV) as described by the ACGIH, for heat stress. Exceeding the TLV is prohibited, and could result in serious injuryor death to workers. When applicable, the WBGT will be monitored by industrial hygiene technicians during both day and night shifts. Data will be evaluated by a Certified Industrial Hygienist (CIH), who will determine the TLV based on the factors listed in this section. EE&G’s CIH is available to assist with Heat Stress Monitoring.

Workers should be instructed to periodically monitor their heart rate during periods of high ambient temperatures, or periods involving heavy work. A maximum, sustained heart rate of 100 beats per minute should result in the temporary removal of a worker from the exclusion zone.

The primary method of minimizing the adverse effects of heat stress will be through the implementation of a work/rest regiment, expressed as a percentage of time out of each hour that a worker can perform their respective task. The unadjusted TLV for heat stress is presented below. Designated rest areas should be outside of the exclusion zone (no PPE requirements), and should be in an air-conditioned environment. Temperatures are shown as degrees Fahrenheit (°F):

Workload Work/rest regiment Light Moderate Heavy Continuous Work 86 80 77 75% work/25% rest 87 82 78 50% work/50% rest 89 85 82 25% work/75% rest 90 88 86

29

NYC-WTC_000150366

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000150366Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →