buildings in lower Manhattan were sampled, and four comparison buildings were sampled
from the area north of 59th Street In the 30 lower Manhattan buildings, the following
locations were sampled: 59 residential units, 29 common areas, and 29 outdoor areas.
There were 127 air samples taken from 117 different areas of the lower Manhattan
buildings. Ten of the areas had co-located sampling equipment. In the 59 different
residential units, there were 64 air samples taken. Thirty air samples were taken from 29
different common areas.
Samples taken from the four comparison buildings above 59th Street included three outside
air samples, three of common areas with both indoor settled surface dust and air, and five
residential units with both indoor settled surface dust and air. No outside settled surface
dust samples were collected because there was no visible dust to collect.
Tables 3,4, and 5 show the number of buildings and areas within the buildings that were
sampled for asbestos, SVF, and minerals in lower Manhattan and the comparison units
above 59th Street. The tables also show whether the samples were settled surface dust and
air samples.
C. Field and Laboratory Changes From the Original Sampling Protocol
Once the sampling teams went to the various sampling locations, it was determined that
some changes needed to be made to the sampling protocol. The sections below indicate the
changes that were made to the original sampling protocol.
I. Field Changes
The sampling protocol indicated that a total of 60 residential units would be tested in
lower Manhattan. A total of 59 residential units were sampled.
Indoor settled surface dust was collected using EPA’s Environmental Response Team
Standard Operating Procedure (ERT SOP) for household dust, as stated in the sampling
protocol. However, due to cost and equipment availability constraints. Omega Ultivac
vacuums with high efficiency particulate air (HEPA) filters were used instead of Nilfisk™
vacuums. To avoid the need to decontaminate the vacuum hose between each sampling
event, a sample collection filter (Alsock, by Midwest Filtration) was inserted into the air
intake end of the vacuum hose. The Alsock has a 97% capture of particles with diameters
of 1.1 microns and larger. The ERT SOP-specified vacuum bag filter has a 4- to 5-micron
pore size.
Instead of one settled surface dust sample per unit, two co-located indoor settled surface
samples were collected. This change was made as two different laboratory locations were
involved in the analysis. The EMSL Analytical laboratory in New York City analyzed
samples for fibers (using PCM, PLM, and TEM); the EMSL Analytical laboratory in
Westmont, New Jersey, analyzed samples for the remaining materials and conducted the
SEM analysis for fibers.
14
NYC-WTC_000149715