NYC 9/11 Public Portal Document
“Even on the worst air days in Beijing, downwind from coal-fired power plants, or in the Kuwaiti oil
fires, we did not see these levels of very fine particulates,” Cahill said. The amounts of very fine
particles, particularly very fine silicon, decreased sharply during the month of October.
Coarse particles
Similar to the high concentrations of very fine particles, virtually all the air samples from the trade
center site carried high concentrations of coarse particles—those about 12 micrometers to 5
micrometers in diameter.
“These particles simply should not be then ,” Cahill said. “It had rained, sometimes heavily, on six
days in the prior three weeks. That rain should have settled these coarse particles.” The finding
suggests that coarse particles were being continually generated from the hot debris pile. This
observation is at least quo..tatively supported, for while they are still being analyzed, the coarse
particles appear to be coated with combustion products, including soot, Cahill said.
Metals
Many different metals were found in the samples of very fine particles, and some were found at
the highest levels ever recorded in air in the United States.
However, there are few established safety guidelines for airborne metals. One metal for which
there is a guideline, lead, was present at low levels in fine and very fine particles.
Some of the metals for which there are no guidelines that were present in very fine particles in
relatively high concentrations were iron, titanium (some associated with powdered concrete),
vanadium and nickel (often associated with fuel-oil combustion), copper and zinc. Mercury was
seen occasionally in fine particles but at low concentrations. Many of those metals are widely
used in building construction, wiring and plumbing. Some are common in computers.
The metal content of the coarse particles is still being analyzed.
Asbestos and glass
Although some asbestos was used in the buildings for fireproofing and in floor tiles, and the
DELTA group checked for it carefully using the electron microscope, they found very few
asbestos fibers, even in the very fine particles.
Some particles that appeared to be glass were seen, but they were not in the form of long shards,
which can mimic asbestos fibers.
Clean-up recommendations
All evidence indicates that ambient air in New York City now is little influenced by the World
Trade Center collapse, especially since the fires are out and the debris pile has cooled.
However, the presence of large amounts of very fine particles as late as October means that
indoor clean up should be done carefully, Cahill said. Very fine particles will have penetrated
crevices and fabrics in a way normal dust doesn’t. And they are easily re-suspended, which re
exposes the room’s occupants to them.
Cahill strongly supports the recommendations made by the New York Department of Health
regarding washing with water, and said:
• Don’t use vacuum cleaners or brooms because they re-suspend particles. Do use wet rags,
mops and wet-vacuum-type cleaners.
• Wipe all surfaces, including window blinds, picture top' uiu door frames, with wet rags.
• Drapes and curtains should be washed or dry-cleaned. Furniture fabrics should be steam-
cleaned. Carpets should be wet-cleaned.
• Use high efficiency electrostatic or HEPA air filters in furnaces and air conditioners.
• Keep humidity reasonably high indoors, to keep very fine particles from floating around.