NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/AIR MONITORING - LAB
Document / 85 pages

EPA air monitoring chain of custody, Jan 2003

Machine-extracted title · confidence 95%

A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.

NYC-WTC_000149346–000149430

Folder label: “AIR MONITORING - LAB

Page image
Scanned page image, NYC-WTC_000149384
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

§763.91 40 CFR Ch. I (7-1-00 Edition) (4) An action may also be considered erence was approved by the Director of complete If the volume of air drawn for the Federal Register in accordance each of the five samples collected with­ with 5 U.S.C. 552(a) and 1 CFR part 51. in the affected functional space is The method is incorporated as it exists equal to or greater than 1,199 L of air on the effective date of this rule, and a for a 25 mm Alter or equal to or greater notice of any change to the method than 2,799 L of air for a 37 mm filter, will be published in the FEDERAL REG­ and the average concentration of asbes­ ISTER. tos as analyzed by the TEM method In (6) To determine the amount of appendix A of this subpart E, for the ACBM affected under paragraph (i)(5) five air samples does not exceed the Al­ of this section, the local education ter background level, as deAned in ap­ agency shall add the total square or pendix A, of 70 structures per square linear footage of ACBM within the con­ millimeter (70 s/mm^). If the average tainment barriers used to isolate the concentration of asbestos of the five functional space for the action to re­ air samples within the affected func­ move, encapsulate, or enclose the tional space exceeds 70 s/mm^. or If the ACBM. Contiguous portions of materied volume of air in each of the samples is subject to such action conducted con­ less than 1,199 L of air for a 25 mm fil­ currently or at approximately the ter or less than 2,799 L of air for a 37 same time within the same school mm filter, the action shall be consid­ building shall not be separated to qual­ ered complete only when the require­ ify under paragraph (i)(5), of this sec­ ments of paragraph (i)(3) or (i)(5), of tion. this section are met. [52 FR 41846, Oct. 30. 1987, as amended at 53 (5) At any time, a local education FR 12525, Apr. 15. 1988; 60 FR 31922, June 19, agency may analyze air monitoring 1995; 60 FR 34465, July 3, 1995] samples collected for clearance pur­ poses by phase contrast microscopy § 763.91 Operations and maintenance. (PCM) to confirm completion of re­ (a) AppIicabHity. The local education moval, encapsulation, or enclosure of agency shall implement an operations, ACBM that is greater than small-scale, maintenance, and repair (O&M) pro­ short-duration and less than or equal gram under this section whenever any to 160 square feet or 260 linear feet. The friable ACBM Is present or assumed to action shall be considered complete be present in a building that It leases, when the results of samples collected owns, or otherwise uses as a school in the affected functional space and building. Any material identiAed as analyzed by phase contrast microscopy nonfriable ACBM or nonfrlable as­ using the National Institute for Occu­ sumed ACBM must be treated as friable pational Safety and Health (NIOSH) ACBM for purposes of this section Method 7400 entitled "Fibers” pub­ when the material is about to become lished in the NIOSH Manual of Analyt­ friable as a result of activities per­ ical Methods, 3rd Edition, Second Sup­ formed in the school building. plement, August 1987, show that the (b) Worker protection. The protection concentration of Abers for each of the provided by ERA at 40 CFR 763.121 for five samples is less than or equal to a worker protection during asbestos limit of quantitation for PCM (0.01 A- abatement projects is extended to em­ bers per cubic centimeter (0.01 f/cm^) of ployees of local education agencies who air). The method is available for public perform operations, maintenance, and inspection at the Office of the Federal repair (O&M) activities involving ACM Register, 800 North Capitol Street, NW, and who are not covered by the OSHA Suite 700, Washington, DC, 20408, and asbestos construction standard at 29 the Non-Confidentlal Information Cen­ CFR 1926.58 or an asbestos worker ap­ ter (NCIC) (7407), Office of Pollution proved by OSHA under section 19 of the Prevention and Toxics, U.S, Environ­ Occupational Safety and Health Act. mental Protection Agency, Room B-607 Local education agencies may consult NEM, 401 M Street, SW., Washington, appendix B of this subpart if their em­ DC, 20460, between the hours of 12 p.m. ployees are performing operations, and 4 p,m, weekdays excluding legal maintenance, and repair activities that holidays. This Incorporation by ref­ are of small-scale, short-duration.

658

NYC-WTC_000149384

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149384Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

19 shared non-person entities · Same agency, volume and box · similarity 0.961

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →