NYC 9/11 Public Portal Document
Environmental Protection Agency §763.88
area that is greater than 5,000 ft^, ex ysis under the EPA Interim Asbestos
cept as provided In § 763.87(c) (2). Bulk Sample Analysis Quality Assur
(b) Thermal system Insulation. (1) Ex ance Program until the NBS PLM lab-
cept as provided In paragraphs (b) (2) oratoiy accreditation program for PLM
through (4) of this section and is operational.
§ 763.87(c), an accredited inspector shall (b) Bulk samples shall not be compos
collect. In a randomly distributed man ited for analysis and shall be analyzed
ner, at least three bulk samples from for asbestos content by PLM, using the
each homogeneous area of thermal sys “Interim Method for the Determina
tem Insulation that is not assumed to tion of Asbestos in Bulk Insulation
be ACM. Samples” found at appendix E to sub
(2) Collect at least one bulk sample part E of this part.
from each homogeneous area of (c)(1) A homogeneous area is consid
patched thermal system insulation ered not to contain ACM only if the re
that is not assumed to be ACM if the sults of all samples required to be col
patched section is less than 6 linear or lected from the area show asbestos in
square feet. amounts of 1 percent or less.
(3) In a manner sufficient to deter (2) A homogeneous area shall be de
mine whether the material is ACM or termined to contain ACM based on a
not ACM, collect bulk samples from finding that the results of at least one
each insulated mechanical system that sample collected from that area shows
is not assumed to be ACM where ce that asbestos Is present in an amount
ment or plaster is used on fittings such greater than 1 percent.
as tees, elbows, or valves, except as (d) The name and address of each lab
provided under § 763.87(c) (2). oratory performing an analysis, the
(4) Bulk samples are not required to date of analysis, and the name and sig
be collected from any homogeneous nature of the person performing the
area where the accredited inspector has analysis shall be submitted to the per
determined that the thermal system son designated under §763,84 for inclu
Insulation is fiberglass, foam glass, sion into the management plan within
rubber, or other non-ACBM. 30 days of the analysis.
(c) Miscellaneous material. In a man
ner sufficient to determine whether (52 FR 41846, Oct. 30. 1987. as amended at 60
material is ACM or not ACM, an ac FR 31922, June 19, 1995]
credited Inspector shall collect bulk § 763.88 Assessment.
samples from each homogeneous area
of friable miscellaneous material that (a)(1) For each inspection and rein
is not assumed to be ACM. spection conducted under §763.85 (a)
(d) Nonfrlable suspected ACBM. If any and (c) and previous inspections speci
homogeneous area of nonfrlable sus fied under §763.99, the local education
pected ACBM is not assumed to be agency shall have an accredited inspec
ACM, then an accredited inspector tor provide a written assessment of all
shall collect, in a manner sufficient to friable known or assumed ACBM In the
determine whether the material is school building.
ACM or not ACM, bulk samples from (2) Each accredited inspector pro
the homogeneous area of nonfrlable viding a written assessment shall sign
suspected ACBM that is not assumed to and date the assessment, provide his or
be ACM, her State of accreditation, and if appli
cable, accreditation number, and sub
§763.87 Analysis. mit a copy of the assessment to the
(a) Local education agencies shall person designated under §763.84 for in
have bulk samples, collected under clusion in the management plan within
§763,86 and submitted for analysis, ana 30 days of the assessment.
lyzed for asbestos using laboratories (b) The inspector shall classify and
accredited by the National Bureau of give reasons in the written assessment
Standards (NBS), Local education for classifying the ACBM and suspected
agencies shall use laboratories which ACBM assumed to be ACM in the
have received Interim accreditation for school building into one of the fol
polarized light microscopy (PLM) anal- lowing categories:
655
NYC-WTC_000139270