DATE: 08/24/01

WORLD TRADE CENTER 'AIR MONITORING TABLE Fiber Asbestos Duration: "Sample : PCM , Concy; 4;Conc. Date Ambient/ Sampled - Volume : LOQ - PCM AF TEM Sampled :: #77 Sample ID Location Sampled PERIMETER SAMPLES NYC-WTC_000148568

09/12/01 10912/A207001 GREENWICH & CHAMBERS ST. AMBIENT 95 950 0.080 overload 39/12/01 10912/A207002 CENTRE & CHAMBERS ST. AMBIENT 90 . 900 0.016 123.73 09/12/01 10912/A207003 SPRUCE & GOLD ST AMBIENT 95 950 0.040 157.48 09/12/01 ' 10912/A207004 BROADWAY & WORTH ST AMBIENT SO 500 0.010 44.99 NYC 9/11 Public Portal Document

09/12/01 10912/A207005 W.BROADWAY & WORTH ST AMBIENT 35 350 0.010 11.25 PERIMETER SAMPLES 09/13/01 10913/A207001 MURRAY & CHURCH ST. 25 AMBIENT 375 0.220 09/13/01 10913/A207002 FULTON & CHURCH ST. AMBIENT 40 600 0.100 09/13/01 10913/A207003 MURRAY & GREENWICH ST. AMBIENT 40 . 600 f 08 4.00. 09/13/01 10913/A207005 LIBERTY & CHURCH ST. AMBIENT 30 450 0.01 <LOQ 09/13/01 10913/4207004 WASHINGTON & CEDAR ST. AMBIENT 30 450 0.01 <10Q Limit of PERIMETER SAMPLES 09/14/01 10914/A003001 MURRAY & CHURCH ST. AMBIENT 40 600 0.008 <LOQ 09/14/01 10914/A003002 FULTON & CHURCH ST. AMBIENT 40 600 0 007 Quantification 09/14/01 10914/A003007 MURRAY & GREENWICH ST. AMBIENT SO 750 0.006 <1.0Q 09/14/01 10914/A003003 LIBERTY & CHURCH ST. AMBIENT 40 600 0.020 09/14/01 10914/A003004 CHEDAR & TRINTY PL AMBIENT 39 585 0.027 09/14/01 10914/A003008 MURRAY BETWEEN CHURCH & BROADWAY AMBIENT 40 600 0.002 09/14/01 10914/A003009 FULTON BETWEEN CHURCH & BROADWAY AMBIENT 30 450 0.01 HOT ZONE SAMPLES 09/14/01 10914/A003005 1 LIBERTY PLAZA - APPROX. 50 FT FROM EXPLOSION SO AMBIENT 750 0.007 09/14/0] 10914/A003006 PARK & GREENWICH ST .- APPROX. 50 FT. FROM EXPLOSION AMBIENT 35 525 0,009 DEP FACILITY 09/14/01 10914/A207006 184 AVE D, DEP PUMPING STATION - FOUR BAY AREA INDOOR 65 975 0.00$ PERIMETER SAMPLES 09/1 5/0110915/A307001 MURRAY & CHURCH ST. AMBIENT 3S 525 0.022 09/15/01 302-1 FULTON & CHURCH ST. AMBIENT 40 600 0.034 09/15/01 LAB3#2 MURRAY & GREENWICHI ST. AMBIENT 45 675 0.031 09/15/01 LABI#2 LIBERTY & BROADWAY AMBIENT SO 750 0.008 09/15/01 LAB3#3 CEDAR & BROADWAY AMBIENT 30 450 0.033 09/15/01 10915/A307003 BROADWAY & MURRAY ST AMBIENT 30 450 0.045 09/15/01 10915/A307002 MURRAY BETWEEN CHURCH & BROADWAY AMBIENT 50 750 0.024 09/15/01 LABI#I FULTON BETWEEN CHURCH & BROADWAY AMBIENT 4S 675 0.035 HOT ZONE SAMPLES 09/15/DI LAB3#1 GREENWICH & PARK PL AMBIENT 30 450 0.076

METHODS: 1. PCM : NIOSH 7400 METHOD, "A" COUNTING RULE. 2 TEM : EPA 40 CFR PART 763 FINAL RULE (AHERA) Page 1 of 6

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148568Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer

Compare copies and versions →