NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/AIR ASBESTOS MONITORING REPORTS
Document / 428 pages

Legal hold notice for WTC documents, undated

Machine-extracted title · confidence 98%

Notice instructing staff to preserve original World Trade Center documents for potential legal actions against the City.

NYC-WTC_000148192–000148619

Folder label: “AIR ASBESTOS MONITORING REPORTS

Page image
Scanned page image, NYC-WTC_000148502
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Non-Potable Water Tests for Freon 22 World Trade Center Path Station Level B6 Collection Date: 10/1/01 . Units: µg /L

Parameter Sample 1 Sample 2 Sample 3 Sample 4 Large Pool of Water Large Pool of Water Small Pool of Water Small Pool of Water East Side East Side WTC Westside Path Tracks Westside Path Tracks ---

Chlorodifluoromethane (Freon 22) 441 605 28.8 47.3

Non-Potable Water Tests for Salinity :

World Trade Center Path Station Level B6 · Collection Date: 10/1/01 Units: ppt practical 1

Parameter Sample 1 Sample 2 Small Pool Water Small Pool Water Westside Path Tracks Westside Path Tracks

Salinity 18.0 18.0

B6 Level (Path Station) 10/1/01

02 20.9%

H2S 6 -8 PPM

LEL 0 PPM

CO OPPM

PID 0 PPM

FID 0 PPM

Freon 22 0 PPM

58 NYC-WTC 000148502

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148502Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer

Compare copies and versions →