NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/AIR ASBESTOS MONITORING REPORTS
Document / 428 pages

Legal hold notice for WTC documents, undated

Machine-extracted title · confidence 98%

Notice instructing staff to preserve original World Trade Center documents for potential legal actions against the City.

NYC-WTC_000148192–000148619

Folder label: “AIR ASBESTOS MONITORING REPORTS

Page image
Scanned page image, NYC-WTC_000148417
OCR text

OCR status: ok · source: pdftotext

. DATE: 09/24/01

WORLD TRADE CENTER AIR MONITORING TABLE Fiber Ashestas Sample POM Con: Lout. TEM Sample 50 (struc./mm2) NYC-WTC_000148417

PERIMETER SAMPLES 9/72/01 10912/A207001 GREENWICH:A . LAMPES' 0.080 overload 9/12/01 10912/A207002 CENTRE & CHAMBERS ST AMBIENT 100 0.016 123.73 9/12/00 10912/A207003 SPRUCE & GOLD ST AMUSENT 95 950 0 040 157.48 9/12/01 10912/A207004 BROADWAY & WORTH ST AMBIENT 50 500 0.010 -44.99 NYC 9/11 Public Portal Document

9/12/0! 10912/A207005 W.BROADWAY & WORTH ST AMBIENT 35 350 0.010 11.25

PERIMETER SAMPLES 9/13/01 10913/A207001 MURRAY & CHURCHIST AMBIENT 25 375 0.220 0/13/01 10913/A207002 FULTON & CHURCH ST. AMBIENT 40 0.100 9/1.7/01 10913/A207003 MURRAY & GREENWICH ST 40 600 0.008 <LOQ :9/1 3/01 10913/A207005 LIBERTY & CHURCH ST. AMBIENT 30 450 0.01 <1.00 9/13/01 1091.W/A207004 WASHINGTON & CEDAR ST 450 0.0} <10Q

PERIMETER SAMPLES 19/1 2/01 10914/A003001 MURRAY & CHURCH SI 40 0.008 .LOQ 10014/A003002 007 10014/10010007 MIRRAY & GRI! KEST 750 0.006 14/14/0! PERTY & TWOROOST 39/14/03 AMINT 39 0.027 39/14/01 MURRAY BETWEEN . IT RCH & BROADWAY 40 600 0.002 09/14/01 10914/A00309 HA.TON BETWHEN CHURCH & BROADWAY AMBIENT 30 450 0.01 <LOQ HOT ZONE SAMPLES 19/14/01 10914/A002005 1 LIBERTY PLAZA - APPROX. 50 FT FROM EXPL.OSNUIN AMBIENT 50 750 0.007 <LOQ 19/14ANI 10914/A003006 PARK & GREENWICH ST. - APPROX. 50 FT. FROM EXPLOSION AMBIENT 35 525 0.009 BANHM LABORATORY UNIT

DEP FACILITY 19/14/01 10914/A207006 184 AVE D, DEP PUMPING STATION - FOUR NAY ARHA INDOOR 65 975 0.005

PERIMETER SAMPLES 10915/A307001 MURRAY & CHURCH ST. AMBIENT 35 525 0.022 '0 39/15/01 302-1 FULTON & CHURCH ST AMBIENT 60G 0.034 09/15/01 LAB3#2 MURRAY & GREENWICH ST. AMBIENT 45 675 0.031 39/15/01 LABI#2 LIBERTY & BROADWAY 50 750 09/15/01 LAB3#3 CEDAR & BROADWAY AMMENT 30 450 0.033 39/15/01 10915/4307003 BROADWAY & MURRAY ST AMBIENT 4.50 09/15/01 10915/A307002 MURRAY BETWEEN CHURCH & BROADWAY AMMENT 50 750 0.024 09/15/01 LABI#I FULTON BETWEEN CHURCH & BROADWAY 45 675 HOT ZONE SAMPLES 1:3/15/01 LAB3#1 GREENWICH & PARK PL AMBENT 30 450 0.076 SEP-24-2001 22:26

METHODS: 1. PCM : NIOSH 7400 METHOD, "A" COUNTING RULE. 2 TEM . EPA 40 CFR PART 763 FINAL RULE (AHERA) Page 1 of 6

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148417Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer

Compare copies and versions →