NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/AIR ASBESTOS MONITORING REPORTS
Document / 428 pages

Legal hold notice for WTC documents, undated

Machine-extracted title · confidence 98%

Notice instructing staff to preserve original World Trade Center documents for potential legal actions against the City.

NYC-WTC_000148192–000148619

Folder label: “AIR ASBESTOS MONITORING REPORTS

Page image
Scanned page image, NYC-WTC_000148319
OCR text

OCR status: ok · source: pdftotext

-Kenata consulting SServices, Inc. P.05/05 fax 201 678 1789 304 Edgemoni Terrace Teaneck NJ 07666 201 692 7967 TOTAL P. 05

Certificate of Analysis NYC-WTC 000148319

Project Location: WTC, NYC Analysis Date: October 8, 2001 Client: Riverpoint, Inc RCS Project # 099 Client #: 101171 Work Area: N/A - 718 595 4690 NYC 9/11 Public Portal Document

. · PCM Air Sample Analysis Summary Fibers Fickbs Demity Fiber Conc. Flow Rate Duration Vokune Lab ID Client ID Sample Description Collected Liters/min. 675 13 100 16.56 0.009 10/8/01 15.00 45 2563 011008 Park Place and Church 14.75 45 663.75 10 100 12.74 0.007 10/8/01 0.006 2564 031008 Murray and Church 14.50 61 884.5 10.5 100 13.38 10/8/01 7.64 0.003 2585 021008 Park Place and Greenwich 61 899.75 6 100 10/8/01 14.75 2566 041008 Murray and Greenwich 45 663.75 12 100 15.29 0.009 10/8/01 14.75 0.007 2567 071008 West Street and Warren 45 630 9.5 100 12.10 10/8/01 14.00 25$8 061008, Warren and North End 45 630 9 100 11.46 0.007 10/8/01 14.00 2569 171008 North End and Park Place 45 652.5 3 100 3.82 <BDL 10/8/01 14.50 2570 151008 River Terrace and Chambers 45 630 6 100 7.64 0.005 10/8/01 14.00 2571 161008 River Terraca and Warren 45 675 4.5 100 5.73 <BDL 10/8/01 15.00 2572 141008 |Park Place and River Terrace 652.5 4 100 5.10 <BOL 10/8/01 14.50 45 2573 181008 Vesey and River Terrace 0 0 0 100 0.00 NIA 10/8/01 0.00 0.00 NIA 2574 F81 Field Blank 1 0.00 0 0 0 100 10/8101 2575 FB2 Field Blank 2 49 735 5.5 100 7.01 0.004 ide 10/8/01 15.00 2576 121008 3rd Place and West End and Waters 48 720 2 100 2.55 <BOL end of West Thame s 10/8/01 15.00 0.004 2577 131008 West 51 752.25 6 100 7.64 10/8/01 14.75 2578 111008|Rector Place by park 15.00 48 $20 11 100 14.01 0.007 10/8/01 2579 191008 Trinity Place and Thames 15.00 50 750 7 100 8.92 0.005 10/8/01 NYCDEP DERTA 2580 051008 Fulton and Church 55 803 3 100 3.82 <BDL 10/8/01 14.60 2581 081008 Galeway Plaze 50 730 3 100 3.82 <BDL 10/8/01 14.60 2582 091008 South End Avenue and Albany 45 666 17 100 21.66 0.013 1018/01 14.80 2583 101008 West and Albany 50 730 N/A 100 N/A 10/8/01 14.60 2584 201008 Vesey and West Broadway

Analysis Method: Phase Contrast Microscopy, NIOSH Method 7400 ELAP ID No. 11750 Expires 12:01 AM, April 1, 2002 Limit of Quantitation (LOQ) = 102 [Fiber/mm2] Limit of Detection (LOD) = 7 [Fiber/mm2] · Sample Overloaded

Analysis Performed By: OCT-09-2001 11:42

Marek Pawlik Laboratory Director

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148319Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer

Compare copies and versions →