NYC 9/11 Public Portal Document
Study
Common Areas
Vestibule, Elevator, Stairwells, Hallways, Utility Rooms, Trash Chute Accesses and Laundry
Room.
Cleaning Method: Test 4A, 4B - Surface cleaning using industrial filtered vacuums. Air
filtration utilizing an air filtration device (AFD). Soap and water wet wipe of all horizontal and
vertical surfaces.
Equipment Used: Nilfisk™ Vacuum (CFM 127), AFD.
Filtration Status: HEPA
Unit Size: Four Levels Total: 2,556 sq. ft.; 30,492 cu. ft.
Hallways (per level) 639 sq. ft.; 7,623 cu. ft.
Vestibule 150 sq. ft.; 1,500 cu. ft.
Elevator Compartment 48 sq. ft.; 384 cu. ft.
Laundry Room (Included as hallway)
Utility Rooms (Included as hallway)
AFD Status: Required
AFD Specifications: 400/600 cfm
Unit Air Exchange Rate: 19.5 min at 400 cfin (hallway)
Minimum Air Exchange Required: Every 30 minutes
Description: The vestibule is located on Cedar Street and provides access to the building’s
only elevator and one stairwell. A second stairwell is accessed from Liberty Street. Four
hallways connect the two stairwells and elevator access point on each floor (2"** floor to 5*
floor). Each hallway contains a utility room with a trash chute access. The laundry room is
located off of the 2*^ floor hallway. The common areas contain no porous building material. All
walls and ceilings in the stairwells are painted. Carpeting is not present in any of the common
areas. Minimal dust was observed in the common areas.
Difficult Areas Encountered:
• The common areas were used daily by all individuals working in the building. These areas
were frequently damp mopped to control the migration of dust.
• Dust accumulations were heavy at the base of the walls where the baseboard trims were
removed.
• Hallway walls were vacuumed, but not wet wiped as a result of wallpaper paste residue left
when the wallpaper was removed prior to the pilot study.
14