NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 06/DEP 59.17 Junction Blvd, 11th FL
Document / 17 pages

EPA Indoor Air Quality Glossary of Terms, Oct 1997

Machine-extracted title · confidence 100%

Document defining indoor air quality terms such as acid aerosols and action levels for radon remediation.

NYC-WTC_000142802–000142818

Folder label: “DEP 59.17 Junction Blvd, 11th FL

Page image
Scanned page image, NYC-WTC_000142817
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document . Indoor Air Quality Page 16 of 18

I ne researcners laehtinea buu vuus in inaoor air in rour ouiioings (a school, two homes for the elderly, and an office building) and determined that Concentrations of certain terget VOCs are elevated in buildings due to emissions from certain building materials (measuremente were taken from 16 such materials). Concentrations of compounds such as xylene and decane were elevated in the new building at completion of construction but fell off markedly within six months. Study was lirnited in scope and duration, made no extrapolations or estimates of VOC distribution frequency in public buildings, and recommended further study involving different types of buildings and many more types of building materials. A copy of the study report may be obtained from the National Technical Information Service in Springfield, Virginia. U.S. EPA, EPA Document Number 600ZS6-88/009a. September 1988.

Project Summary: Indoor Air Quality in Public Buildings: Volume II

Summarizes results of companion study to that reported by Volume I. Six buildings were sampled for VOCs (a hospital, two homes for the elderly, two office buildings, and an institute for governmental studies). The. new buildings had high concentrations of aromatic and aliphatic hydrocarbons immediately after completion but concentrations declined by an order of magnitude within several months. Building materials emitting these chemicals at the highest rates were surface coatings such as adhesives, caulking, and paints; wall and floor coverings such as molding, linoleum tile, and carpeting; and miscellaneous other materials such as vinyl telephone cables. Researchers surmised that renovation or refurbishment of buildings would also result in temporarily higher concentrations of these chemicals. A copy of the study report may be obtained from the National Technical Information Service in Springfield, Virginia. U.S. EPA, EPA Document Number 600/S6- 88/009b, September 1988.

Project Summary: Compendium of Methods for the Determination of Air Pollutants In Indoor Air

Summarizes research project which developed a Compendium of Methods for the. Determination of Air Pollutants in Indoor Air. The Compendium provides regional, state, and local environmental regulatory agencies with standardized, step-by-step sampling and laboratory analysis procedures for the determination of selected pollutants in indoor air. A core set of ten chapters, with each chapter containing one or more methods, covers VOCs, carbon monoxide and carbon dioxide, air exchange rate, benzo(a)pyrene and other polynuclear aromatic hydrocarbons, and several other contaminants. A copy of the full document may be obtained from the National Technical Information Service in Springfield, Virginia, U.S. EPA, EPA Document Number 600/S4-90-O10, May 1990.

Introduction to indoor Air Quality: A Self-Paced Learning Module

The Indoor Air Quality Learning Module and its companion document, the Indoor Air Quality Reference Manual, provide an introduction to indoor air quality for environmental health professionals. Primary focus is on residential indoor air quality. Documents cover those aspects of indoor air quality important for establishing an indoor air quality program by a state or local government agency. Developed under a cooperative arrangement between the National Environmental Health Association, the Bureau of .Health Professions of the U.S. Public Health Service, and AU CDA CDA

http://www.epa.gov/iaq/pubs/index.html 4/8/02

NYC-WTC_000142817

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000142817Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Cited alongside this record in an Ask answer

Compare copies and versions →