ADDENDUM #2 World Trade Center Dust Cleaning Program Monitoring Contract Scope of Work

that was present in the ventilation system prior to or after the WTC collapse. In these cases, bulk dust sampling will be performed.

3.0 APPLICABLE DOCUMENTS

This section provides full bibliography for references made within this document. Evaluations should be conducted in a manner that is fully compliant with the guidance provided in the following documents, to the extent applicable.

ACR 2002, Assessment, Cleaning and Restoration of HVAC Systems, National Air Duct Cleaning Association, Washington, D.C. (2002).

Section 3 of ACR 2002 includes procedures for performing a visual assessment of HVAC systems required in item 6.5.2.1 of this document.

NADCA Standard 97-05, Requirements for the Installation of SetMce Openings in HVAC Systems, National Air Duct Cleaning Association, Washington, D.C. (1997).

NADCA 97-05 includes procedures for installing service openings in HVAC systems and construction and material specifications for replacement panels, plates or access doors to cover such openings as required under item 6.5.1.2 of this document.

SMACNA HVAC Duct Construction Standards - Metal and Flexible, Sheet Metal and Air Conditioning Contractors’ National Association, Inc., 2"^ Edition (1995).

The SMACNA standard includes construction and material specifications for access doors for covering service openings as required under item 6.5.1.2 of this document.

SMACNA Fibrous Glass Duct Construction Standards, Sheet Metal and Air Conditioning Contractors’ National Association, Inc., 6*’’ Edition (1992).

The SMACNA standard includes construction and material specifications for access doors for covering service openings as required under item 6.5.1.2 of this document.

NFPA Standards 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, and 90B, Standard for the Installation of Warm Air Heating and Air-Conditioning Systems, National Fire Protection Association (1999 Edition).

The NFPA standards include construction and material specifications for replacement coverings on service openings as required under item 6.5.1.2 of this document.

OSHA Regulations 29 CFR 1910, Occupational Health and Safety Standards

The OSHA regulations specify health and safety requirements for protecting employees during the inspection procedures.

NYC-WTC_000140291

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140291Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000140281 · Box DEP Box 05

Draft contract scope defining regulations and procedures for asbestos cleanup and air sampling assistance programs in Lower Manhattan.

Filed in the same folder

Compare copies and versions →