EPA memorandum regarding asbestos reservoir, June 2002

Machine-extracted title · confidence 50%

Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.

NYC-WTC_000140083–000140124

Folder label: “EPA Cate Jenkins

Page image
Scanned page image, NYC-WTC_000140090
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

f

T

preferable to test a piece from a flat, upper horizontal surface which would be more contaminated.

ASTM microvacuum method is inadequate for carpets and other woven fabrics

Some argue that testing carpet and fabrics with the hand-held ASTM microvacuum suction pump would be a good enough test, since it would get out the easily releasable asbestos. In this method, carpet and other fabrics are sampled by a hand-held air suction pump. The fabric is essentially vacuumed by the pump. The asbestos is caught on a filter, and then the filter is sent to the lab for testing.

However, this ASTM microvacuum sampling pump is only a first-line test for carpet and other woven fabrics, and is not definitive. The microvacuum pump does not apply any greater suction than a good vacuum cleaner. High impacts, such as a child running or rolling on the carpet, will release much more asbestos than any vacuuming process. The EPA ultrasonication method will extract over 100 times the amount of asbestos from carpet compared to the ASTM micro vacuum method. The ultrasonication method is also an official EPA method specific to carpet, and is thus preferred.’

NYC APT. BUILDING USES ULTRASONIC CARPET TESTING

The New York Environmental Law and Justice Project'” obtained carpet samples from one NYC apartment building on Hudson St., near the intersection with Thomas St. The samples were taken on May 29, 2002, over 8 months after the collapse of the WTC. The samples were tested by EPA’s ultrasonication method. The results are given in Table 1. The building is 9 blocks north of Ground Zero, and 4 blocks north of Warren St. Warren St. was defined by the New York City Department of Health as the northernmost point of contamination from WTC fallout.

The building does not have central forced air heating and cooling. Heat is by floorboard hot water pipes. Air conditioning is by individual window units. There is forced air circulation in the hallways only. The building is a well maintained with a clean boiler room and basement. As seen in a later section of this memo, these levels are high, indicating a major asbestos release. The pattern of the contamination, roof and lower hallway, is indicative of the asbestos source being the World Trade Center.

-6-

NYC-WTC_000140090

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140090Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →