4 shared non-person entities · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195823
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000195823–000195827
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Another idea would be to take a carpet sample from the center of hallway, and then replacing just the center of the hallway with contrasting carpeting. An inset rectangle or diamond shape would be very attractive.
For common areas in a building, a carpet-type floor mat could be tested if there is concern about cutting out a piece of a rug or wall-to-wall carpeting. First, purchase a replacement mat yourself. Then, retrieve, replace, and test the old mat.
A long narrow strip from the hem of draperies can be used for the samples, or the drapery lining can be used. For upholstered furniture, a side that does not show can be tested, but it would be preferable to test a piece from a flat, upper horizontal surface which would be more contaminated.
Superiority and advantages of the ultrasonication carpet test
Some argue that testing carpet and fabrics with the hand-held ASTM microvacuum suction pump would be a good enough test, since it would get out the easily releasable asbestos. In this method, carpet and other fabrics are sampled by a hand-held air suction pump. The fabric is essentially vacuumed by the pump. The asbestos is caught on a filter, and then the filter is sent to the lab for testing.
However, this ASTM microvacuum sampling pump is only a first-line test for carpet and other woven fabrics, and is not definitive. The microvacuum pump does not apply any greater suction than a good vacuum cleaner. High impacts, such as a child running or rolling on the carpet, will release much more asbestos than any vacuuming process. The EPA ultrasonication method will extract over 100 times the amount of asbestos from carpet compared to the ASTM microvacuum method. The ultrasonication method is also an official EPA method specific to carpet, and is thus preferred.’
The most meaningful asbestos test that a resident can have, whether or not they have a consultant to take samples, is EPA’s ultrasonication extraction test for carpeting, draperies, or upholstery fabric. Over 100 times the amount of asbestos will be found in carpet using EPA’s ultrasonication test, compared to the ASTM microvacuum sampling method.^
An ultrasonication test may be the best way to tell if asbestos is present in a residence or office. Carpeting and upholstered fabric can be tested to see if it needs abatement, or it can be tested after abatement to determine whether it was decontaminated. Hard smooth surfaces may show no asbestos contamination with the ASTM microvacuum method if tested soon after cleaning. But carpeting cannot be cleaned effectively, and will show any residual asbestos.
-4-
CITY_21MC100_011117886
NYC-WTC_000195826
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000178146
Memorandum listing laboratories offering EPA's ultrasonication test for asbestos structures in carpets and fabrics.
22 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
4 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144624
EPA report detailing microscopy methods for assessing asbestos fiber contamination in carpeting.
6 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
7 shared non-person entities · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
7 shared non-person entities · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
7 shared non-person entities · similarity 0.919
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
4 shared non-person entities · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093086
Laboratory analysis detecting and quantifying chrysotile asbestos structures in carpet samples.
5 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154652
Internal tracking document for managing reports, comments, and actions related to environmental compliance cases.
6 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105578
Administrative file header identifying records related to the property at 61 Broadway.
3 shared non-person entities · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000178146
Memorandum listing laboratories offering EPA's ultrasonication test for asbestos structures in carpets and fabrics.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000178146
Memorandum listing laboratories offering EPA's ultrasonication test for asbestos structures in carpets and fabrics.
Similar indexed content
NYC-WTC_000140127
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similar indexed content
NYC-WTC_000144624
EPA report detailing microscopy methods for assessing asbestos fiber contamination in carpeting.
Similar indexed content
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similar indexed content
Similar indexed content