Part III — Health & Safety Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701— Rev 3, August 29, 2005

incident to the Building. The SSO will provide the "all clear" signal to the contractor site managers once it is safe to return to normal work operations.

2.16 Response to Specific Emergency Events

Below is a list of unplanned events that may occur during the deconstruction project. This list may not be all encompassing, but represents "events" related to similar projects. These events include: • Fire or explosion • Power failure • Structural failure • Worker injury or illness

2.16.1 Fire or Explosion

In the event of an explosion or a fire, the SSO shall immediately: 1. Call 911 2. Initiate building evacuation procedures as outlined in Section 2.15 of this HASP 3. Meet First responders at the pre-designated location (unless circumstances dictate otherwise, it is the security desk at the Building) for briefing on the scope and nature of the emergency 4. Notify OWNER

Should there be a work stoppage in a certain area due to a fire or an explosion, work will not resume until the SSO verifies that appropriate corrective actions have been taken.

2.16.2 Power Failure

In the event of a power failure, the SSO shall immediately: 1. Call 911, if warranted 2. Coordinate with the site manager and abatement contractor to initiate containment isolation activities (e.g. both the Personnel and Waste Load Out Decontamination units must be immediately sealed to prevent a fiber release). 3. All containment isolation barriers are to remain secure until the required negative pressure has been re-established.

2.16.3 Structural Failure

Deconstruction process will create weakened sections as supporting elements are removed, such as roof sheathing, wall sheathing. In the event of a unanticipated structural failure, the SSO shall immediately:

1. Call 911, if warranted

37

NYC-WTC 000134404

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000134404Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →