Part II - Environmental Community Monitoring Plan
133-135 Greenwich & 21-23 Thames Streets
Airtek Project 05-0701— Rev 2 September 16, 2005
Examples of non-compliance include not wearing appropriate PPE; Improper documentation;
Failure to collect field blanks or duplicates; Improper sampling equipment; Unauthorized changes
in sampling locations or sampling procedures; Improper field equipment decontamination; not
properly calibrating equipment; and improper handling of samples or equipment.
The following QA/QC documentation must be met for all samples:
• Sample documentation (location, date and time of collection, etc.);
• Chain of Custody;
• Initial and continuing calibration;
• Sampling design approach;
• Determination and documentation of detection limits;
• Analyte(s) identification;
• Analyte(s) quantification;
• QC and Performance Evaluation samples.
3.1 Chain of Custody
All samples must be transferred without exception to the appropriate analysis station under chain
of custody. Standard Chain of Custody must be used for this purpose.
3.2 Sample Shipment
Samples are to be treated in an appropriate and suitable manner for delivery to the analytical
laboratory. All packaging and labels shall comply with Federal Department of Transportation
regulations as provided in 49 CFR 171-178. Specific requirements for sample shipment are
outlined in the QAPP.
3.3 Quality Assurance Manual Methods for PM10
Measures of accuracy, precision, and additional measurement quality objectives for
PM10 measurements are summarized on Table A-1. The same procedures may be used for
TSP and lead samplers when monitoring for these. Because of US EPA requirements, a different
set of procedures is used for PM2.5.
A manual PM monitoring system consists of a sampling system at
the site, an analysis system at a central location and a
transportation system to get the sample filters from one to the
other. The system components will function within the limits of the
applicable performance specifications given in 40 CFR parts 50 and 53
Monitoring program procedures will also be in general accordance with
the guidance and recommendations of applicable sections of the "Quality
Assurance Handbook for Air Pollution Measurement Systems, Volume
I,(EPA/600/R94/038a) and "Quality Assurance Handbook for Air Pollution
Measurement Systems, Volume II, Part 1,(EPA-454/R-98-004).
The sampling system consists of a sampler (one or more at each site) and a human sample
collection staff who loads new (unexposed) filters into the sampler, sets it to sample the filter for
24 hours (normally midnight to midnight) on a specified day, and retrieves the exposed filter
afterward.