NYC 9/11 Public Portal Document
New Vin 1 I, , h
307W .., s< et, 6'a=,.,., York, NY I
21
Attn: CTSI-Consulting & Testing Services, Inc. Customer ID: CTS150
622 Georges Rd. Customer PO:
North Brunswick, NJ 08902
Received: 09/28/01 5:30 PM
Fax: (732) 729-1803 Phone: 732-729-1800
EMSL Order: 030105088
Project: 115 Broadway / Entire Bldg EMSL Project ID:
Analysis Date: 9/29/2001
Fiber A i.alysis of Ali; ammm 1es via NOSH 7400. Revision 3, Issue 2, 8/15/9
LOD Fibers/ ihcrrs/
Sample Location Sample Duct' I'olrnne /,hers Fields (Jib c) nun' cc ,'Votes
13 5th FI West side 9/28/2001 1905.00 <5.5 100 0.001 <7,0 <0.001
030105088-0013
14 5th FI Center 9/28/2001 1905.00 <5.5 100 0.001 <7.0 <0.001
030105088-0014
15 5th FI East side 9/28/2001 1905.00 <5.5 100 0.001 <7.0 <0.001
030105088-0015
16 4th FI West side 9/28/2001 1980.00 6.0 100 0.001 7.64 0.002
030105088-0016
4th FI Center 9/28/2001 1980.00 <5.5 100 0.001 <7.0 <0.001
)30705088-0011
18 4th FI East side 9/28/2001 1980.00 <5 5 100 0.001 <7.0 <0.001
030105088-0018
19 3rd Fl West side 9/28/2001 1950.00 15.0 100 0.001 19.11 0.004
030105088-0019
20 3rd FI Center 9/28/2001 1950.00 16.5 100 0.001 21.02 0.004
030105088-0020
21 3rd FI East side 9/28/2001 1950.00 8.0 100 0.001 10.19 0.002
030105088-0021
22 2nd FI West side 9/28/2001 1875.00 <5.5 100 0.001 <7.0 <0.001
030105088-0022
23 2nd FI Center 9/28/2001 1875.00 <5.5 100 0.001 <7.0 <0.001
030105088-0023
24 2nd FI East side 9/28/2001 1875.00 <5.5 100 0.001 <7.0 <0.001
030105088-0024
.. .ar/: ✓
Rey Cross
Analyst Laboratory Manager
or other approved signatory
roil of deli~ct;r n is 7 fihe rshnn~' the h~boi story is not responsible for dataceported
reported in fiberfiec, which is dependent on vi In collected by non-laboratory personrel This report
reran s only3 et the sarrples p reported ebho toy report ma y rot be forp except in 'ul l , without written approval by EMSL.
Anal,y pnrIornrred by EMSL Manhattan (NY State FLAP #11506)
CM-1 2
---------------------------- ---------------
NYC-WTC 000132934
OCR can misread numbers and units. Confirm readings against the page image before using them.