NYC 9/11 Public Portal Document
Attn: CTSI-Consulting & Testing Services, Inc. Customer ID: CTSI50
622 Georges Rd. Customer PO:
North Brunswick, NJ 08902 Received: 09/28/01 5:30 PM
Fax: (732) 729-1803 Phone: 732-729-1800
EMSL Order. 030105088
Project: 115 Broadway I Entire Bldg EMSL Project ID:
Analysis Date: 9/29/2001
Fiber Analysis of Air Samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94
LOD Fibers,' Fibers/
Sample Location SampleDate Volume Fibers Fields (fib/cc) mm' cc Notes
13 5th FI West side 9/28/2001 1905.00 <5.5 100 0.001 <7.0 <0.001
030105088-0013
14 5th FI Center 9/28/2001 1905.00 <5.5 100 0.001 <7.0 <0.001
0301050880014
15 5th Fl East side 9/28/2001 1905.00 <5.5 100 0.001 <7.0 <0.001
030105088-0015
16 4th Fl West side 9/28/2001 1980.00 6.0 100 0.001 7.64 0.002
030105088.0016
17 4th Fl Center 9/28/2001 1980.00 <5.5 100 0.001 <7.0 <0.001
030105088-0017
18 4th FI East side 9/28/2001 1980.00 <5.5 100 0.001 <7.0 <0.001
030105088-0018
19 3rd Fl West side 9/28/2001 1950.00 15.0 100 0.001 19.11 0.004
030105088-0019
20 3rd FI Center 9/28/2001 1950.00 16.5 100 0.001 21.02 0.004
030105088-0020
21 3rd Fl East side 9/28/2001 1950.00 8.0 100 0.001 10.19 0.002
030105088-0021
22 2nd FI West side 9/28/2001 1875.00 <5.5 100 0.001 <7.0 <0.001
030105088-0022
23 2nd FI Center 9/28/2001 1875.00 <5.5 100 0.001 <7.0 <0.001
030105088-0023
24 2nd F1East side 9/28/2001 1875.00 <5.5 100 0.001 <7.0 <0.001
030105088-0024
•
Rey Cross
Analyst Laboratory Manager
or other approved signatory
Limit of detection is 7 fibers mm'. The laboratory is not responsible for data reported in fiberelcc, which is dependent on volume collected by non-laboratory personnel. This report
relates only to the samples reported above. This report may not be reproduced, except In full, without written approval by EMSL
Mal ó performed by EMSL Manhattan (NY State ELAP #11506)
1 2
NYC-WTC 000133067
OCR can misread numbers and units. Confirm readings against the page image before using them.