Lead Based Paint Removal Technical Specifications For 130 Cedar Street New York, NY 10006 PART 1-GENERAL

0 1.01 INTRODUCTION

A. This document addresses environmental, administrative and engineering controls to be undertaken by the contractor when disturbing any building component coated with paint containing lead at levels greater than or equal to 1.0 mg/cm2 (Lead Based Paint).

1.02 GENERAL PROVISIONS

A. All work which disturbs surfaces that are coated with lead based paint must be performed in accordance with the Occupational Safety and Health Administration (OSHA) 29 Code of Federal Regulation (CFR) Part 1926.62, Lead Exposure in Construction; EPA 40 CFR Part 745 Lead; Requirements for Lead-Based Paint Activities in Target Housing and Child-Occupied Facilities, Final Rule; the New York State Department of Health Rules & Regulations and the New York State Department of Environmental Conservation (NYSDEC) code 6 New York Code of Rules & Regulations (NYCRR) subparts 371-376. In addition, all other applicable federal, state and local codes, rules and regulations must be adhered to by the Contractor.

B. The Contractor shall be aware that Lead Based Paint has been identified within the proposed demolition project and must be familiar with the OSHA lead in construction standard and its requirements. In addition, all waste generated as part of the renovation project should be tested in order to determine the classification of the waste. The United States Environmental Protection Agency (USEPA) defines Hazardous Waste as waste containing the minimum concentration of a particular contaminant identified by the Toxicity Characteristic Leaching Procedure (TCLP). The USEPA regulatory level for lead (EPA Code: D008) is 5 PPM (parts per million).

C. The Contractor shall supply all equipment and materials necessary to perform the work. All electrical power (including Ground Fault Circuit Interrupters for the HEPA vacuums, temporary lighting and any other electrical needs) shall be supplied by the Contractor.

Prepared by JLC Environmental Consultants, Inc. Project No. 04-3271 02085-1

NYC-WTC 000125677

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125677Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →