JLC Environmental Consultants, Inc.
200 Park Ave. South - Suite 1001, New York, NY 10003
Phone: (212) 420-8119 - Fax: (212) 420-6092
Project No: 04-3271
Masterworks Development Corp. ELAP Lab Code: 11029
Analyze: ASBESTOS
56 West 45th Street NIOSH and AIHA Lab Code: 100273
Date Received 12/03/2004
New York NY 10036 NVLAP Lab Code: 101953-0
Date Analyzed: 12/03/2004
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0404586
SITE: 130 Cedar Street
SAMPLE #
Asbestos Non-Asbestos
COLLECTED DESCRIPTION / LOCATION COLOR Asbestos Constituents Constituents
LAB # Detected? (%) (*/o)
019 F Ceiling Skimcoat, Sample Not Analyzed
12/02/2004 5th Floor/ South East Area/ Near Fan at
0404586-019 Window/ East Side/ Sample of Black
Painted Ceiling Skimcoat
020 F Ceiling Skimcoat, Sample Not Analyzed
12/02/2004 5th Floor/ South East Area/ Near Fan at
0404586-020 Window/ North Side/ Sample of Black
Painted Ceiling Skimcoat
*Insufficient material submitted **TEM recommended ***Not analyzed positive stop
Sample Analysis by:
Polarized light Microscopy-Dispersion Staining (PLM-DS)
Method of Sanmle Preparation and Analysis:
All samples were prepared and analyzed in accordance with the EPA "Method for the Determination of Asbestos in
Bulk Building Materials" USEPA/ 600/R-93/l 16, July, 1993
b mentatioer
Olympus P114I, Model BH-2/VM stexeomicroscope Model VMZ lx-4x.
Analytical results reflect the make up of the materials only in the areas sampled This "Summary of Analytical Results" shall not be reproduced except
in full, without the written approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the
U.S. Government. This method is not applicable to samples containing large amounts of fine fibers below the resolution of the light microscope. The
value of this method is limited to the quantitative identification of asbestos and the sari-quantitative determination of asbestos content of bulk samples,
expressed as a percentage of the projected area. Quantitation of asbestos content was determined with a visual volume estimate, a calibrated visual
area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbestos may give positive interferences
and will be considered asbestos under this methodology. Also, PL241 is not consistently reliable in detecting asbestos in floor coverings and similar
non-friable organically bound materials. Quantitative transmission election microscopy is currently the only method that can be used to determine
if this material can be considered or treated as non-asbestos containing.
Gulam
Page4of4 Report Data december07, 2004