NYC 9/11 Public Portal Document
JLC Environmental Consultants, Inc.
200 Park Ave. South - Suite 1001, New York, NY 10003
Phone: (212) 420-8119 - Fax: (212) 420-6092
Project No: 04-3271
Masterworks Development Corp. ELAP Lab Code: 11029
Analyte: ASBESTOS
56 West 45th Street NIOSH and AIHA Lab Code: 100273
Date Received: 12/03/2004
New York NY 10036 NVLAP Lab Code: 101953-0
Date Analyzed: 12/06/2004
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0404590
SITE: 130 Cedar Street
SAMPLE #
Asbestos Non-Asbestos
COLLECTED DESCRIPTION! LOCATION COLOR Asbestos Constituents Constituents
LAB # Detected? ( */0) (*/*)
7-007B Dust/ Debris, Tan, Non-homogeneous, Tan No
12/03/2004 Friable
0404590-007 7th Floor/ Near South West Column/ Non-Fibrous Material 100%
Floor/ Sample of Dust/ Debris
7-008B Dust/ Debris, Tan, Non-homogeneous, Tan No Cellulose Fiber 2%
12/03/2004 Friable Fibrous Glass 10%
0404590-008 7th Floor/ Exterior Stairwell Landing/ Non-Fibrous Material 88%
West Side Floor of Landing/ Floor/ Sample
of Dust/ Debris
7-009B Dust/ Debris, Tan, Non-homogeneous. Tan No
12/03/2004 Friable
0404590-009 7th Floor/ 10 Feet to West ofSouth East Non-Fibrous Material 100%
Column/ Floor/ Sample of Dust/ Debris
*insufficient material submitted **TEM recommended ***Not analyzed positive stop
Sample Anal sis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS)
Method of Sample Preparation and Analrs1s:
All samples were prepared and analyzed in accordance with the EPA "Method for the Determination of Asbestos in
Bulk Building Materials" USEPA/ 600/R-93/116, July, 1993
Uum ow
Olympus PLM, Model BH-2/VM steeornicroscope Model VMZ lx-4x.
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except
in full, without the written approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the
U.S. Govemntent. This method is not applicable to samples coning large amounts of fine fibers below the resolution of the light microscope. The
value of this method is limited to the gi h.bve identification of asbestos and the semi-quantitative determination of asbestos content of bulk samples,
expressed as a percentage of the projected area. won of asbestos content was determined with a visual volume estimate, a calibrated visual
area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbestos may give positive interferences
and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and similar
non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine
if this material can be considered or treated as non-asbestos containing.
Galan Machhiwala, l Dixactor
Page 2 of 2 Report Date: December 07, 2004
NYC-WTC 000125546