NYC 9/11 Public Portal Document

JLC Environmental Consultants, Inc. 200 Park Ave. South - Suite 10011. New York. NY 10003 Phone: (212) 420-8119 - Fax: (212) 420-6092

S Masterworks Develol 56 West 45th Street New York NY 10036 t Cn'P• ELAI' Cab Code: 11029 NIOSH and AIHA Lab Code: 100273 Project No: Analyze: Date Received: 04-3271 ASBESTOS 05/26/2004 NVLAP Lab Code: 101953-0 Date Analyzed: 05/26/2004 SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0403440 SITE: L 130 Cedar Street

SAMPLE # Asbestos Non-Asbestos COLLECTED DESCRIPTION / LOCATION COLOR Asbestos Constituents Constituents LAB # Detected? (%) (%)

212T3 Boiler Room Air Vent Caulking, Dark Dark No Cellulose Fiber 1% 05/25/2004 Brown, Homogeneous, Non-Friable Brown Fibrous Glass 1% Note: Recommend TEM 0403440-034 Ground Floor/ Loading Dock/ Sample of Non-Fibrous Material 98% Boiler Room Air Vent Caulking

213T3 Boiler Room Air Vent Caulking, Dark Dark No Cellulose Fiber 3% 05/25/2004 Brown, Homogeneous, Non-Friable Brown Note: Recommend TEM 0403440-035 Ground Floor/ Loading Dock/ Sample of Non-Fibrous Material 97% Boiler Room Air Vent Caulking

214U3 Horsehair Pipe Fitting Insulation, Brown, Brown No Hair 100% 05/25/2004 Homogeneous, Friable 0403440-036 Ground Floor/ Loading Dock/ Sample of Horsehair Pipe Fitting Insulation

215U3 Horsehair Pipe Fitting Insulation, Brown, Brown No Cellulose Fiber 8% 05/25/2004 Homogeneous, Friable Hair 92% 0403440-037 Ground Floor/ Loading Dock/ Sample of Horsehair Pipe Fitting Insulation

216U3 Horsehair Pipe Fitting Insulation, Brown, Brown No 90% Hair 05/25/2004 Homogeneous, Friable 0403440-038 Ground Floor/ Loading Dock/ Sample of Non-Fibrous Material. 10% Horsehair Pipe Fitting Insulation

Gulam Machhiwala, Lab Director Page 7 of 8 Report Date: July 06, 2004

NYC-WTC 000125297

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125297Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →