Asbestos and Lead Paint Inspection Report for 130 Cedar Street, New York, NY 10006
1. The Inspector enters the area to be Inspected, Identifies all room equivalents and creates a hand sketch of the area. Room I is to be the room which contains the entry door to the dwelling or facility. Each subsequent room equivalent is then numbered. Room 2 Is designated as the room which is nearest to the left hand side of Room I (if facing the dwelling with back towards the dwelling's primary entrance). Room numbering is then continued in a clockwise fashion.
2. The inspector then identifies each testing combination in Room 1. A testing combination is defined as a unique combination of room equivalent, building component type, and substrate. The color, condition and location of the testing combination is also noted. Locations are designated as follows: Wall u s the wall directly to the back of the Inspector when he or she enters the room equivalent. Subsequent walls are numbered in a clockwise fashion. For example, if the Inspector was noting the location of the entry door of a bedroom, that door would be located on wall 1. If he was noting the location of a window to his left, that window would be located on wall 2. Components such as light fixtures and ceilings are noted as located on the ceiling, and components that are not near a wall are noted as located in the room center.
3. Using the XRF device, the inspector collects readings from all testing combinations In Room 1. •
4. When all testing combinations are tested, the inspector then continues the inspection with the remaining room equivalents.
5. The inspection is finished when all testing combinations in the dwelling or facility have been tested. 3.2 SCOPE OF WORK FOR LEAD BASED PAINT:
The inspection for lead based paint included the following locations:
1. Basement 2. Ground Floor 3. Floor 2-12 4. Main and Bulkhead Roofs 5. Terrace Roofs 6. Exterior Facade
The inspection was characterized by a close visual inspection of all accessible areas. Suspect paints were sampled and inventoried for quantity and condition. Components examined included:
1. Lower Wall ( .j • Prepared for Masterworks Development Corp. By JLC Environmental Consultants, Inc. Project No. 04-3271 Page 37
NYC-WTC 000125242
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000125653
Report detailing asbestos inspection results for the 130 Cedar Street site.
17 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125526
Letter reporting bulk dust sample results confirming the presence of asbestos-containing materials at 130 Cedar Street.
20 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123797
NYC DEP letter to building owner requesting environmental hazard assessments and bulk sample results for WTC-area building re-occupancy.
23 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095478
Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
21 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113372
Fax cover sheet from Alchemy Properties Inc. dated February 19, 2002, regarding records for 38 Warren Street.
17 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104679
Report detailing dust sampling from hospital entrances to determine asbestos content following the September 11 attacks.
10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099164
Letter from DEP Commissioner regarding exterior survey findings of WTC debris and removal efforts at the landmarked building.
6 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131928
Fragmented document page from the Department of Environmental Protection archive.
14 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000109972
Fax cover sheet transmitting asbestos bulk samples from Fiterman Hall to Applied Technology Services for analysis.
5 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
16 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
15 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000125069
A single-page record labeled for 130 Cedar Street with a unique NYC-WTC identifier.
Filed in the same folder
NYC-WTC_000125070
Contractor requirements and site plan notes for demolition work at 30 Cedar Street.
Filed in the same folder
NYC-WTC_000125073
General notes and requirements for demolition work at 130 Cedar Street including contractor qualifications.
Filed in the same folder
NYC-WTC_000125076
Correspondence submitting updated asbestos project documentation to the DEP for 130 Cedar Street.
Filed in the same folder
NYC-WTC_000125098
Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.
Filed in the same folder