Asbestos and lead survey report cover, 130 Cedar Street, July

Machine-extracted title · confidence 100%

Cover page for a survey report detailing asbestos and lead-based paint findings at 130 Cedar Street.

NYC-WTC_000125204–000125524

Folder label: “130 CEDAR STREET

Page image
Scanned page image, NYC-WTC_000125381
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC Environmental Consultants, Inc. 201) Park Ave. South - Suite 1001. New York. NY 110(1.3 Phone: (212) 420-8119 - Fax: (212) 420-6092 Project No: 04-3271 Masterworks Development Corp. ELAP Lab Code: 11029 M 56 West 45th Street NIOSH and AIHA Lab Code: 100273 l : ASBESTOS Date Received: 06/04/2004 New York NY 10036 NVLAP Lab Code: 101953-0 Date Analyzed: 06/07/2004 SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0403533 SITE: #Deleted 130 Cedar Street 1 SAMPLE # Asbestos Non-Asbestos COLLECTED DESCRIPTION / LOCATION COLOR Asbestos Constituents Constituents LAB # Detected? (%) (%)

*Insufficient material submitted **TEM recommended nded ***Not analyzed positive stop Sample Ana)ysis by: Polarized Light Microscopy-Dispersion Staining (PLM-DS) Method of Sammie Prenaration and Analysis: All samples were prepared and analyzed in accordance with the EPA "Method for the Determination of Asbestos in Bulk Building Materials" USEPA/ 600/R-93/116, July, 1993

Olympus PLM, Model BH-2/VM stereornicroscope Model VMZ lx-4x.

Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except intall,

without the written approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency the U.S. Government. This method is notapplicable to samples containing large amounts of She fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the projected area. Quantitation of asbestos content was determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbestos may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

. ___________ Gulam Machhiwala, Lab Director Page 3 of 3 Report Date: July 06, 2004

NYC-WTC 000125381

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125381Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →