NYC 9/11 Public Portal Document

130 Cedar Street July 15, 2004 Selective Demolition and Façade Restoration Koenen Associates A. After mortar has fully hardened, thoroughly clean exposed masonry surfaces of excess mortar and foreign matter, use wood scrapers, stiff-nylon or -fiber brushes, and clean water, spray applied at low pressure.

1. Do not use metal scrapers or brushes. 2. Do not use acidic or alkaline cleaners.

B. Wash adjacent woodwork and other non-masonry surfaces. Use detergent and soft brushes or cloths.

C. Clean masonry debris from roof; remove debris from gutters and downspouts. Rinse off roof and flush gutters and downspouts.

D. Sweep and rake adjacent pavement and grounds to remove masonry debris. Where necessary, pressure wash surfaces to remove mortar, dust, dirt, and stains.

3.11 FIELD QUALITY CONTROL A. Inspectors: Owner will engage qualified independent inspectors to perform inspections and prepare test reports. Allow Inspectors use of lift devices and scaffolding, as needed, to perform inspections. B. Architect's Project Representatives: Architect will assign Project representatives to help carry out Architect's responsibilities at the site, including observing progress and quality of portion of the Work completed. Allow Architect's Project representatives use of scaffolding, as needed, to observe progress and quality of portion of the Work completed.

C. Notify Structural Engineer in advance of times when lift devices and scaffolding will be relocated. Do not relocate lift devices and scaffolding until inspectors and Architect's Project representatives] have had reasonable opportunity to make inspections and observations of work areas at lift device or scaffold location.

END OF SECTION 04901

C

CLAY MASONRY RESTORATION AND CLEANING 04901 -15

NYC-WTC 000125182

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125182Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →