130 Cedar Street July 15, 2004 Selective Demolition and Façade Restoration Koenen Associates

UNIT MASONRY •

PART 1.00 -GENERAL

1.01 GENERAL REQUIREMENTS

A. Work of this Section, as shown or specified, shall be In accordance with the requirements of the Contract Documents.

1.02 WORK INCLUDED

A. The work of this Section Includes all labor, materials, equipment and services necessary to complete the unit masonry work as shown the drawings and specified herein, on

Including but is not necessarily limited to the following:

2. of concrete masonry unit walls io'4, 3. Metal joint reinforcing, anchors, ties, weeps, and related accessories for masonry. 4. Chases, recesses, pockets and openings In masonry/terra cotta as required for Installation of work by others. 5. Building in of items furnished by others into masonry, including access doors, door frames, anchors, sleeves and inserts, and other similar items to be embedded In masonry. 6. Grouting In of metal items built into masonry work. •

1.03 RELATED WORK

A. Furnishing loose lintels - Section 05500. B. Sealant - Section 07900. C. A Lstr+&r.M + a-4i ate—' Scc "t c

1.04 SUBMITTALS A. Samples (Submit the following):

1. Each type of face brick in sufficient number and color to show full range of color and shade. Submit certification that brick meets ASTM standards specified. f,

a. Submit samples of all special shapes required showing color range and sizes.

2. Joint reinforcing, each type, width and proposed locations (labeled). 3. Anchors, wedges and ties, each type; width and proposed locations (labeled). 4. Joint filler, each type. 5. Flashing, Including splice sample, 12" x 12".

B. Manufacturer's literature: Submit technical and installation Information for

Unit Masonry 04200-1

NYC-WTC 000125158

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125158Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →