130 Cedar Street July 15, 2004
Selective Demolition and Façade Restoration Koenen Associates
A. Existing Utilities: Maintain services indicated to remain and protect them against damage
during selective demolition operations. Retain one of two "Utility Requirements" paragraphs
below, if applicable. Delete both if Owner arranges and performs work. •
B. Utility Requirements: Locate, identify, disconnect, and seal or cap off indicated utilities serving
areas to be selectively demolished.
1. Arrange to shut off indicated utilities with utility companies.
2. If utility services are required to be removed, relocated, or abandoned, before proceeding
with selective demolition provide temporary utilities that bypass area of selective
demolition and that maintain continuity of service to other parts of building.
3. Cut off pipe or conduit in walls or partitions to be removed. Cap, valve, or plug and seal
remaining portion of pipe or conduit after bypassing.
3.3 PREPARATION
A. Dangerous Materials: Drain, purge, or otherwise remove, collect, and dispose of chemicals,
gases, explosives, acids, flammables, or other dangerous materials before proceeding with
selective demolition operations.
B. Pest Control: Employ a certified, licensed exterminator to treat building and to control rodents
and vermin before and during selective demolition operations.
C. Site Access and Temporary Controls: Conduct selective demolition and debris-removal
operations to ensure minimum interference with roads, streets, walks, walkways, and other
adjacent occupied and used facilities.
1. Do not close or obstruct streets, walks, walkways, or other adjacent occupied or used
facilities without permission from Owner and authorities having jurisdiction. Provide
0-
alternate routes around closed or obstructed traffic ways if required by governing
regulations.
2. Erect temporary protection, such as walks, fences, railings, canopies, and covered
passageways, where required by authorities having jurisdiction.
D. Temporary Facilities: Provide temporary barricades and other protection required to prevent
injury to people and damage to adjacent buildings and facilities to remain.
1. Provide protection to ensure safe passage of people around selective demolition area and
to and from occupied portions of building.
2. Provide temporary weather protection, during interval between selective demolition of
existing construction on exterior surfaces and new construction, to prevent water leakage
and damage to structure and interior areas.
3. Protect walls, ceilings, floors, and other existing finish work that are to remain or that are
exposed during selective demolition operations.
E. Temporary Enclosures: Provide temporary enclosures for protection of existing building and
construction, in progress and completed, from exposure, foul weather, other construction
operations, and similar activities.
F. Temporary Shoring: Provide and maintain interior and exterior shoring, bracing, or structural
support to preserve stability and prevent movement, settlement, or collapse of construction to
0*
SELECTIVE DEMOLITION 01732-4
NYC-WTC 000125154
OCR can misread numbers and units. Confirm readings against the page image before using them.