Document / 38 pages

HVAC component inventory, 300 Albany St

Machine-extracted title · confidence 100%

List of HVAC components including fans, ducts, and mixing chambers at 300 Albany Street.

NYC-WTC_000116323–000116360

Folder label: “300 ALBANY ST 1000436, 16/7504

Page image
Scanned page image, NYC-WTC_000116352
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation Syste 'isual Inspection Form Page 1 of 2 Ventilation System Identification: A& V tT . RAN4 t N 4 AR*M Tlta a, LtN O OR A'G - Location: 3o0 A t• S AK TETT Area Served: 48l<ti~ L~ t-ti vt: a WI SEeVKC- Aef-~ t 1Zot` N VV-TT cfiw. t 7 PZ-t - Associated mechanical room: clean Y N dry Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC . not present [NOTE: If component not present (NP), not found (NF) or Inaccessible (1) please Debris Dust . not found Indicate In last column] Present? Present? . inacemibM Outside air Intake: Location:

Accessible for inspection? Y V N (explain):

— louvers, grates and/or screens JJ — outside air duct — outside air damper(s) Air handling unit: — outside air mixing chamber (.f j — filter rack(s) 0 — filter media — blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators — blower housing acoustical lining — pre-heat coils f'J? — heating coils — cooling coils — re-heat coils — condensate drain pan — supply air plenum — supply air plenum damper(s) — vibratign collars Supply air distribution: — Supply air ducts Est. total in ft 0 No. locations inspected Jz- Specify type (circle): fibrous glass lined metal masonzv fibrous glass board

— Accessible in-line fire dampers Est. total qty I No. locations inspected M — Accessible turning vanes Est. total qty pi No. locations inspected F — In-line reheat/cooling coils Est. total qty No. locations inspected — Supply air diffusers Est. total qty i No. locations inspected Return air distribution: '- - - Return air ducts Est. total in 8 Q C No. locations inspected 2.. Specifytype (circle):( ) fibrous class lined metal masomv fibrous class bond

— Return air plenum Est. total RA plenum areas I No. locations inspected 1 N — Return air plenum damper Est total qty No. locations inspected — Accessible in-line fire dampers Est. total qty o'L No. locations inspected o NF — Accessible turning vanes Est. total qty oi No. locations inspected 0 f — Return air grilles Est. total qty t No. locations inspected y

NYC-WTC-000116352

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116352Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →