2.1 Central Ventilation System Visual Inspection Form Page I of 2 Ventilation System Identification: ME 14./c... Location: / Area Served: ` ! L•ow vz Aoe~ ~1~1Cr4 Associatedmechanical room: clean Y N dry Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC i; not LNOTEi If component not present (NP), not found (NF) or inaccessible (I) please Debris Dust present Indicate In last column] Present? Present? 4 not found t Inaccessible Outside air intake: Location:

Accessible for inspection? V/ N (explain):

louverl, grates and/or screens ' N outside air duct n outside air damper(s) Air handling unit: outside air mixing chamber -- filter rack(s) - filter media blower assembly incl. blower wheel blower housing, air vanes, in-line noise attenuators blower housing acoustical lining N re-heat coils • heating coils of P • cooling coils ' re-heat coils n! condensate drain pan - • supply air plenum • N supply air plenum damper(s) - N vibration collars Supply air distribution: Supply air ducts Est. total In ft 50 No. locations inspected Specify type (circle) ! fibrous lass lined met masonry Brous glass board ~( N flex-duct w j

Accessible in-line fire dam ers Est. total ty No. locations ins ected N Q Accessible turning vanes Est, total No. locations ins ected In-line reheat/cooling coils Est. total No. locations ins ected /~► Supply air diffusers Est. total gty No. locations inspected 0 Return air distribution: Return air ducts Est. total In ft I0 No. locations inspected I Specify type (circle): eta fibrous glass lined metal mason fibrous class board (.1 flex-duct w o !

Return air plenum Est. total RA plenum areas ( No. locations ins ected l Return air plenum damper Est. total qty No. locations inspected P Accessible in-line fire dampers Est. total qty No. locations ins ected N

NYC-WTC 000135917

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135917Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117345 · Box DEP Box 46

January 30, 2003 letter from Athenica Environmental Services regarding HVAC and environmental inspections at 250 South End Avenue.

Similar indexed content

Compare copies and versions →