JAN-28-2002 04:52 MERRILL LYNCH 212 236 2301 P.05/06

was re-cleaned until all sample results were below these limits. Isolation barriers were removed only after passing this post sampling criteria.

Wcstsidc cleanup and other areas containing dust (1) 1" cleaning — all surfaces were HEPA vacuumed and wet wiped by asbestos certified handlers and supervisors. (2) All areas were inspected by GPS personnel and rc-cleaned as necessary. (3) Asbestos air sample collection and analysis a. PCM, Phase Contrast Microscopy and TEM, (Transmission Electron Microscopy) samples were collected by OPS, a Licensed asbestos consulting firm. b. All post samples were required to be below 0.01 f/cc (PCM) and less than 70 Structures/mm2 for (TEM). If one sample was at or above these limits then the area was re-cleaned until all sample results were below these limits.

Please JJ Final Cleanup Procedure Overview - After the procedures listed below were completed the floor may be reoccupied with no restrictions. direction of A final, detailed fine cleaning was performed by certified asbestos workers under the a specialized disaster recovery firm. The space walls, floors, furniture and personal items were fined cleaned to remove residual dust. All rugs are shampooed to remove contaminates.

Asbestos Final-clearance air sample collection and analysis (1) Asbestos air sample collection and analysis a, PCM, Phase Contrast Microscopy and TEM, Transmission Electron Microscopy samples were collected by OPS, a Licensed asbestos consulting firm. b. All post samples were required to be below 0.01 f/cc (PCM) and less than 70 Structures/mm2 for (TEM). If one sample was at or above these limits then the area was re-cleaned until all sample results were below these limits. (2) Asbestos wipe sampling was collected from surfaces in representative locations and analyzed for the presence or absence of asbestos using the TEM qualitative analytical technique. To be acceptable all results were required to be reported as absent or negative for asbestos present.

Phase III Procedure Overview — The ventilation ductwork was inspected by a trained HVAC specialist. Areas determined to be contaminated were cleaned by a certified duct cleaning firm. All fresh air and compartmental filters were replaced. Both the upper and lower fresh air fans were turned on after filter replacement, cleaning and inspections were complete. As a measure to ensure a safe environment for all occupants, GPS conducted asbestos air sampling for each floor for a 24-48 hour period.

Prepared by GPS Environmental Consultants, Inc Pg 3 of 4

NYC-WTC 000112094

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000112094Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →