Bulk sample analysis report, 222 Broadway, June 2002

Machine-extracted title · confidence 95%

Laboratory bulk sample analysis report for 222 Broadway dated June 17, 2002.

NYC-WTC_000105912–000105941

Folder label: “222 BROADWAY; BN# 1001245

Page image
Scanned page image, NYC-WTC_000105916
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JUN-17-2002 02:01P FROM: TO:12122360041 P:6'14

KM CONSULTANTS 35-40 36th Street long Island City

Jarr.. NewYoik, 11106 Tel: (118)729-1997 Fax: (716)729-1876

BULK SAMPLE ANALYSI$ REPORT CLIENT: CPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 222 Broadway, Manhattan - 23rd,16th,12th, 10th,3rd Floors PROJECT#: Client Sample ID# : 10-I 1 10-12 3-13 3-14 3-15 Lab Sample ID# 02051613-1567 020516B-1568 0205163-1569 02051613-1570 0205168-1571 Sample Location: Center on East Corner South West V ost Side North West Set Back on Set Back Comer on Set Center on Set Center on Set Roof 10th Roof 10th Back Roof Back Roof Back Roof Floor Floor 3rd Floor 3rd Floor 3rd Floor Homogeneity: Yes Yes Yes Yes Yes Sample Description: N/A N/A N/A N/A N/A

Color Or Or Or Or Or Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None Asbestos Present: (Type & Percent) <I%CIIR <I%CHR ND <1%CHR ND Total Percent Asbestos: <1% <1% 0% <1% 0% Other Fibr Mat. (Type & Percent) 0% 0% 85%FBGL 0% 85%FBOL 2%CELL Non Fibr. Mat. (Percent): >99% >99% 15% >99% 13% Date Received: 5/16/02 Date of Analysis: 5/16/02 Date ofReport: 5/17/02

Analyst:\ . ~ Lab Manager: Roody Lou' David Chen Analysis of samples is performed by Polari? Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial N 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 NIST--NVLAP # 102047 AIHA A 100269

Page 3 of 3

NYC-WTC 000105916

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105916Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →