NYC 9/11 Public Portal Document
JUN-19-2002 1.2:39 MERRILL LYNCH P.10/16
KAM CONSULTANTS
35.4036thStreet
Long lslandCity
NewYork,tt108
Tel:(118)739.1991
jcarr
Fax:(118)7291376
BILK SAMPLE ANALYSIS REPORT
CLIENT; GPS Environmental Consultants, Inc, 31 Treacott Path, Fort Sailonga, New York, 11768
BUILDING ADDRESS: 222 Broadway, Marthattan - 23rd,16th,l2th,10tb,3rd Floors
PROJECT#:
Client Sample ID# 23.01 19.02 16-03 16-04 12-05
Lab Sample 1D# . 0205160-1577 020316C-1578 020516C-1579 020516C-1580 020516CG1581
Sample Location- North Side on West Side On Set South Side on South West South Side on
Set Back Roof Back Roof Set Back Roof Cumer on Set Set Back Roof
23rd Ploor 19th Floor 16th Floor Back Roef (6th I2th Fleur
Floor
H m ogeneitt - Yes Yes Yes Yes Yes
Sample Description: Wipe Wipe Wipe Wipe Wipe
Color: WIt Wit Wh Wls Wh
Texture: Mitred Mixed Mixed Mixed Mixed
Semple Treatment! None None None t4onc None
Asbestos Present:
(Type & Yercent) ND Ni) ND ND <1a/DCHR
Total Percent
Asbestos; 0% 0% 0% 0% <1%
Other Fibr. Mat.
(Tvpe&Present): <1%FBGL 1%SYNTc1 <1%C}-LL <1%CELL 0%
Non Fihr Mat
(Percent) >99% 99% >99% a99% >99%
Date Received: 5/16/02
Date of Analysis: 5/16/02
Date of Report: 5/17/02
Anai'sh - d Lab Manager: !)' Cq' )
Ready Lout' David Chen
• Analysis of samples is performed by ?o1ariz9ttiht Microscopy (PLM) - Point Counting Method
(EPA 600/M4.92.020)
* Analytical equipments: Sterreobinoculer microscope (1v IJ1 F.Mf Serial # 25930), Polarized Light Microscope
(MEIJI ML-POOL-Serial # 88034)
• PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron rn:croscopy is currently the only method that can be used
to determine if this material can be considered or treated ss non-asbestos-containing
° Samples will be stored for ninth, (90) days and then returned to the client upon
request
• The results relate only to the items calibrated or tested
• The certlteate of report shall not be reproduced without the stsitten approval of the laboratory
• The report must be used by the client
not
endorsement by NVLAP or orb} agency of the U5 Govertuttent.
to claim
102047
100269
ELAP # 11273
DOH N1ST-N67--AP #
NYS 4IHA
Page 1 of 2
000105935
NYC-WTC
OCR can misread numbers and units. Confirm readings against the page image before using them.