NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/DEP Box 37/222 BROADWAY; BN# 1001245
Document / 30 pages

Bulk sample analysis report, 222 Broadway, June 2002

Machine-extracted title · confidence 95%

Laboratory bulk sample analysis report for 222 Broadway dated June 17, 2002.

NYC-WTC_000105912–000105941

Folder label: “222 BROADWAY; BN# 1001245”

Page image
Scanned page image, NYC-WTC_000105929
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JUN-19-2002 12:36 MERRILL LYNCH P.04/16

KAM CONSULTANTS 35-4138th Street Long Island City Ner York, !1106 Tel: (118)129.1991 Fax: (118j 729.1970

CLIENT: GPS Environmental Consultants, lot:., 31 Trescott Path, Fort Salooga, New York, 11768 BLLILDING ADDRESSr 222 Broadway. Menbattaa -29tb,24tb,23rd,22nd,20tb,lgtb,16th,i5th Floors PROJECT#: Client Sample (D#: 01-29 02.29 03.24 04-23 05-22 Lab Sample ID# : 020514A-1278 020514A-1279 020514A-1280 020514A-1281 020514A-1282 Sample Location: 29th Floor Cooling 29th Floor Cooling 24th Floor Center 23r I Floor S/West 22nd Floor West Tower N/East Tower SEast on Set Back Corner Set Back Cornet Set Back Corner Flashing Corner Flashing Roof Flashing Roof Flashing Roof Flashing Romogcncity: Yes Yes Yes Yes Yes Sample Description: Wipe Wipe Wipe Wipe Wipe

Color: Wh/Bm Wh Wh Wh/Gr Gr#Wh Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 06/s 0% 0% 0% Other Fibr. Mat. (Type & Percent): <IYeFBGL <I%SYNTH I%SYNTH Iv/.CELL <t°/.CELL 5%SYNTH Non Fibr. Mat. (Percent): 94% >99% 99% 99% >99.1a Date Received. 5114/02 Date of Analysis; 5/14/02 Date of Report: 5/15/02

Analyst:` [too Lobs Lab Maaagert, ~ ~..- --- \ David Ch" j' • Analysis of samples is performed Polarized Light Microscopy (PLM'- Point Counting Method (EPA 600/M4-$2-020) • Analytical equipments: Stareobinocular :tticroscooe (N EIJI EMT•Scrial 9 25930), Polarized Light Microscope (MEUI ML-POi.•Seriel # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar nor(-fliable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request • The results relate only to the items calibrated or tested. 'The certifcate of report shall not be reproduced without the written approval of the laboratory. • The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NY.S=DOH EL.AP # 11273 NIS7-N L4P 0102041 ,4JNA N: 100269

Page 1 of 2

NYC-WTC 000105929

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105929Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196108

Report of air monitoring using phase contrast microscopy for asbestos at the 16th floor roof of 222 Broadway.

Similar indexed content

Compare copies and versions →