I All isolation barriers, and polyethylene intact.
Decon clean and intact, all posted materials in place.
fry' () () Proper wet methods employed, no large piles of debris.
I ' ° () All personal protective equipment in use.
,Y c> () Negative air filtration unit and shower filters in place.
pr c> c> Licensed supervisor on site.
1rY' 0 0 Workers licensed, licenses and names recorded.
'' 0 0 OSHA monitoring performed.
I Negative air filtration hose (snakes) intact.
c6' () o Water off and shower pan emptied at end of day's abatement.
0 Negative air filtration units running 24 hours per day e.g. left vmning at
end of day and found running at the beginning of the day.
I sa- 0c> 0 Workers following proper entering and exit procedures.
Sufficient equipment available.
Y 0
0 All waste double bagged and wetted prior to waste load out.
0 0 Conventional waste deoantaminatad before waste load out.
0 Copies of waste transport tickets supplied to Trumann representative.
0 0 Negative air pressure maintained readings.
0 Air sampling taken of adjacent areas, clean room, REPA exhaust.
Corrective action taken if any air tests above 0.01 goo and the
prcabatement base I' dings.
P } Fail0
Name
Name
If any NO space is checked off, please explain the rca4son.
Comments (unusual events, ctc.):
I
I
I