Engineering report re: structural inspection, Nov 2001

Machine-extracted title · confidence 100%

Letter from Acticon detailing a structural inspection of cracks at 98-100 Greenwich Street following the WTC collapse.

NYC-WTC_000104842–000104844

Folder label: “98 GREENWICH STREET Block: 53 Lot: 38 BIN: 1001055 96-100 Greenwich Street

Page image
Scanned page image, NYC-WTC_000104842
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

4'

A -C IF I C 4) % November 7, 2001 ACT-2588

Mr. Glenn Kriger 98-100 Realty, LLC P.O. Box 1055 Fair Lawn, New Jersey 07410

Subject: Engineering Services for Inspection of crack damages at the 98-100 Greenwich St. Building New York. New York

Reference: Acticon letter ACT-2580 dated October 29, 2001.

Dear Mr. Kriger:

In accordance with the referenced letter, Acticon has conducted a structural inspection of the front and rear building walls at 98-100 Greenwich Street in New York City on November 1, 2001. The purpose of the inspection was to determine whether the observed masonry cracks were as a result of the World Trade Center collapse. The structural inspection was based on visual observations of the front facade, rear facade, roof, 4th floor, as well as a limited inspection of the cellar.

The building at 98-100 Greenwich Street is a five (5) story building with commercial space at the ground floor. The building is constructed of brick masonry bearing walls and wood floor joists. The floor joists frame between the exterior walls and an interior masonry bearing wall at the center of the building.

There are two (2) substantial vertical cracks in the exterior masonry walls. One crack occurs in the rear wall directly adjacent to the interior masonry bearing wall. ' Thiscrack

originates at the top of the wall and extends down the building approximately 8 to 10 feet. At the top, the crack is approximately %z inch wide and appears to go through the entire width of the wall. As it extends down the wall, it tapers in width to a hairline crack. Above the crack the coping stone has separated by approximately 1 inch at a mortar joint.

Acticon Engineering, P.C. 21 North Main Street, Ste. 210 TEL (914) 690-2745 Website: www.acticon-inc.com Port Chester, New York 10573 FAX: (914) 690-2748 E-mail: [email protected]

NYC-WTC 000104842

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000104842Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →