NYC-WTC_000120258
Letter enclosing two reports summarizing asbestos testing data for 41 Park Row sent to the DEP.
12 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗Consultant letter confirming visual review and bulk sample collection of dust at 106 Fulton Street.
NYC-WTC_000104596–000104614Folder label: “106 FULTON STREET Block: 78 Lot: 20 BIN: 1001195 14 Dutch Street”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
CORPORATION Occupational Health, Safety & Environmental Consultants
February 25, 2002 Mr. R. Radhakrishnan, P.E. New York City Department of Environmental Protection Director, Asbestos Control Program 59-16 Junction Boulevard Corona, NY 11368-5107 Via Fax: 718.595.4422
Re: Pace University Property 106 Fulton Street, NY, NY
Dear Mr. Radhakrishnan,
Thank you for taking the time to talk with me on February 19, 2002 regarding your letter of February 17, 2002 (attached) that was issued to our client, Pace University. As I mentioned, the 106 Fulton Street building has been unoccupied since before September 11, 2001.
In response to your February 17th letter and in accordance with our conversation of February 19th, on February 19`t' a Colden Corporation NYC licensed asbestos investigator conducted a visual review of the exterior of 106 Fulton Street and collected ten bulk samples of dust from exterior surfaces. Samples were analyzed by Scientific Laboratories using Polarized Light Microscopy (PLM). Scientific Laboratories is an AIHA accredited and ELAP certified laboratory. A summary of the surfaces sampled and corresponding analytical results are presented below.
Sample ID Surface sampled Asbestos content in dust # 106-1 Roof — NW corner on parapet wall <1 % # 106-2 13°' floor exterior window ledge <1 % # 106-3 8 floor exterior window ledge <1 % # 106-4 8 floor exterior window ledge <1 % # 106-5 2" floor exterior window ledge <1 % # 106-6 Top of exterior construction elevator car <1 % # 106-7 15th floor exterior construction bridge <1 % # 106-8 10 floor exterior construction bridge <1 % # 106-9 7 floor exterior construction bridge <1 % # 106-10 4 floor exterior construction bridge <1 %
All sample analysis results are less than one-percent asbestos. Laboratory reports, chain of custody records and field data sheets in support of this data are attached.
It is our understanding that the City requires the building owner to remove accumulations of dust from exterior building surfaces. And, that asbestos handler licenses are not required for cleaning non-ACM dust, including dust reported to contain less than one-percent or trace asbestos as detected under PLM.
Robert Morris Building • 100 North 17th Street, 9th Floor • Philadelphia, PA 19103 Tel 215 496 9237 • Fax 215 496 9280 • Toll Free 800 586 5580 • www.colden.com
PT NYC-WTC 000104596
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000120258
Letter enclosing two reports summarizing asbestos testing data for 41 Park Row sent to the DEP.
12 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093400
A license agreement document regarding exterior cleaning services for the property at 65 Liberty Street.
6 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125801
Cover sheet for a fax transmission from DEP regarding the 105 Duane Street site file.
5 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131053
Fax cover sheet dated February 20, 2002, transmitting chain of custody records related to Pier 40 and West Street.
8 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
6 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123541
Invoice from Asbestos Removal Corp dated August 6, 2002 for roof cleanup services at 29 Broadway.
6 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000101848
Invoice submitted by a contractor to the Department of Environmental Protection for services rendered.
3 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112013
Inspection form recording facade conditions and debris at the World Financial Center site.
6 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
7 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131129
Letter from Vimar Realty responding to DEP requests for building contamination assessment at 83 Worth Street.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
8 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155920
Header page of a chain of custody document from the DEP Bureau of Air, Noise, and related services.
7 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000120258
Letter enclosing two reports summarizing asbestos testing data for 41 Park Row sent to the DEP.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120258
Letter enclosing two reports summarizing asbestos testing data for 41 Park Row sent to the DEP.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120258
Letter enclosing two reports summarizing asbestos testing data for 41 Park Row sent to the DEP.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000122512
Form documenting facade inspection results and asbestos monitoring status for 120 Broadway.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119454
Letter from DEP requesting bulk sample results and air monitoring data for a site.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119175
Form recording visual inspection results for the facades of 22 Beaver Street in November 2001.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000124304
Laboratory report from ATC Associates providing transmission electron microscopy results for air samples collected at 99 Church Street.
Cited alongside this record in an Ask answer
NYC-WTC_000131492
Chain of custody and cover letter for transmission electron microscopy analysis of air samples from apartments at 125 Liberty Street.
Cited alongside this record in an Ask answer
NYC-WTC_000135145
EPA/DEP memo discussing initial findings from PCB analysis of caulking and dust samples, with risk-based screening criteria evaluation.
Cited alongside this record in an Ask answer