NYC 9/11 Public Portal Document
I ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
A C Associates Inc. Approved N.Y. State ELAP #10879
1 4 East 25th Street ACCREDITED NVLAP Lab Code # 1187
N w York, NY 10010 Report Date: 10/25/01
ASBE TOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: HERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sam le Id ntification Analysis Parameters
Project/S te: Tribeca, 105 Duane St., NY, NY TEM Sample Nc.: 5762 - 62219
Various Sites
Date Rec ived: 10/25/01 Grid Openings Analyzed: 6
Project ample No.: 5 Average Grid Opening: 106.00 um
Air Volu e: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter e: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
- - - -------------------------------------------------------------------------------------------------------------------------
FIBRO IS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. =sum Struct/mm2 Struct/cc nom/m3
Chrysoti a Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total as( :stOS (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals ( 1 Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-a bestos fiber i.d. (EDS/SAED) None detected
Amphi ole Asbestos Type: None detected
------------------------------------------------------------------------------------------------------------------------
---------
I The nalysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
An lyzed by: Report Reviewed by:
Ma ek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC 000104044